ACF6000 Series
ACF6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement.
The ACF6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.
FEATURES
 ● Can be programmed by infrared light sensor without opening cover
 ● High turndown ratio of flow rate
 ● It comes any flanges such as ANSI, DIN, JIS… etc
 ● Excellent for high pressure application
 ● Simple for installation, commission and maintenance
 ● Self-diagnostic capabilities, cable faults, pipe vibration
 ● High accuracy of +/-0.2% of reading (or +/-0.1% of reading)
 ● With forward / reverse flow rate measurement function
SPECIFICATION
| Sensor Type: | Display: | 
| C tube (10-40mm) / U tube (50-150mm) | 2 lines LCD with illumination | 
| Size: | Flow Rate Unit | 
| 10mm ~ 200 mm (3/8″ ~ 8″) | g/s, Kg/min, kg/Hr, T/Hr, 5 Digit | 
| Flow Range: | Density Unit | 
| 0 – 1000 Kg/Hr ~ 0 – 1106000 Kg/Hr | Kg/m3, g/cc, 5 Digit | 
| Accuracy: | Totalizer Unit | 
| +/-0.2% +/-ZS of reading (Standard) | g, Kg, Ton, L, M3, 11 Digits | 
| +/-0.1% +/-ZS of reading (Optional) | Temperature | 
| Repeatability: | oC,  oF, 4 Digits | 
| +/-0.03% +/-ZS of reading | Keypad: | 
| Density Range: | Infrared light  Sensor, | 
| 200 – 2300 Kg/M3 (0.2 – 2.3 g/cm3) | can be programmed without | 
| Accuracy | Opening the cover | 
| +/-0.002 g/cm3 | Turndown Ratio: | 
| Temperature Range: | 20  : 1 | 
| -40 oC ~ +125 oC (Standard) | Damping: | 
| -40 oC ~ +250 oC (Optional, Separate Only) | 0.01 To 1.0 Seconds | 
| Material: | Low Flow Cutoff: | 
| Wetted Parts | 0.0% ~ 9.0% | 
| Stainless Steel 316L | Communication: | 
| Flange | RS485 (Modbus Protocol) (Standard) | 
| Stainless Steel 316L | Hart Signal (Optional) | 
| Sensor Housing | Current Output: | 
| Stainless Steel 304 | 4-20 mA (Isolated) | 
| Junction Box | Load | 
| Aluminum Alloy (Epoxy Paint) | Max. 750   | 
| Process Connection: | Output Unit | 
| Flange  | Mass / Volume / Density / Temperature | 
| Flange Type: | Pulse (Alarm) Output: | 
| JIS 10K / JIS 20K / JIS 40K | Open Collector | 
| ANSI 150# / ANSI 300# / ANSI 600# | Rating | 
| DIN PN 10 / PN 16 / PN25 / PN 40 | 3-30Vdc, 50mA Max. | 
| Protection Class: | Power Supply: | 
| IP 67 | 90-260 VAC, 50/60 Hz  or 24 VDC +/-10% | 
| Explosion Proof Exde (ib) IIC T6 (Optional) | Power Consumption: | 
| Installation: | 30 – 40 W (Depend on sensor size) | 
| Compact or Separate | Cable Entry: | 
| Signal Cable Length: | Sensor to Converter- 3/4″ G | 
| 10M – 100M | Signal output / Power supply- M20 | 
|   | Ambient Temperature: | 
|   | -40 oC to +60 oC | 
|   | Max. Pressure: | 
|   | 63 Kg/cm2
 
  |