AUF760 Series
 
AUF760 series is a fixed mounted, transit-time ultrasonic flowmeter. It features factory mounted transducers that allow it to be flow lab calibrated reducing or eliminating the random or bias error that can be present in clamp-on style transducer mounting.
The meter ensures an accurate, non-invasive measurement of clean homogeneous liquids process.
 
FEATURES
 
● 4 line LCD display with flowrate, totalizer & signal condition  
● Stores up 64 Day / Month / Year Totalizer daily value  
●  Batch control function  
●  Wide range velocities of 0.01 ~ +/- 32 m/s  
●  Pipe size from 100 to 1000 mm  
●  High accuracy of +/-1% of reading  
●  Data logger function, include date, totalizer, signal condition… etc  
●  Response time less than 1 second  
 
SPECIFICATION
 
 
| Measuring Principle: | Keypad: | 
| Transit time difference | 16 Key with tactile action | 
| Pipe Size: | Response Time: | 
| 100 mm ~ 1000 mm | Less than 1 second | 
| 4″ ~ 40″ | Flow Velocity: | 
| Material: | 0.01 ~ +/- 32 m/s | 
| Carbon Steel / Stainless Steel 304 | Resolution: | 
| Stainless Steel316 | 0.0001 m/s | 
| Process Connection: | Ambient Temperature: | 
| Flange  | -20 ~ +50 oC | 
| Flange type: | Mounting: | 
| JIS 7.5K / JIS 10K / JIS 20K / JIS 40K | wall mounting | 
| ANSI 150# / ANSI 300# / ANSI 600# | Max. Cable Length: | 
| DIN PN 10 / PN 16 / PN25 / PN 40 | 300 M | 
| Max. Pressure: | Power Consumption: | 
| 40 Kg/cm2 | Less than 2W | 
| Process Temperature: | Power Supply: | 
| -20 ~ +110 oC | 90 ~ 260Vac 50/60 Hz/ 24Vdc | 
| Display: | Data Storage: | 
| 4 Line LCD with illumination. | Operation parameters and totalization  | 
| Flowrate | figures are stored by EEPROM for more | 
| 5 digit with decimal point | than 10 years | 
| Totalizer | Output: | 
| 8 digit, Forward, Reverse & Net values. | 4-20 mA or 0-20 mA | 
| Engineer Unit | Pulse Output: | 
| M3, Liter, US Gallon, Imperial Gallon, | 1- 9999 Hz | 
| Million Gallon, Cubic Feet, US Barrels, | Data Logger: | 
| Imperial Barrels, Oil Barrel | Limitless overwriting in 64 columns | 
| Time Unit | (Flowrate, totalizer, time, date included)  | 
| Second, Minute, Hour, Day | Alarm: | 
| Other | High/Low with buzzer | 
| Velocity, Date, Time, Signal condition | Communication: | 
| Accuracy: | RS-232 | 
| +/- 1.0% of reading | Dimension: | 
| Repeatability: | 235 * 205 * 95 mm | 
| +/-0.2% of reading | Weight: | 
|   | 1.5 Kg (Converter) | 
|   | Protection Class: | 
|   | Converter | 
|   | IP65 | 
|   | Sensor | 
|   | IP68 (Submersible) |