Enclosure | Weather resistant, chemical resistant, RF/EMI coated high impact polycarbonate polyester blend. Can be set in rain or into 2.5 inches of water without damage. Ergonomically balanced with rugged top mounted handle. |
Dimensions | 10.5" long x 5.9" x 7" tall |
Weight | 5 lbs. |
Detection Principle | Catalytic combustion, electrochemical cell, galvanic cell, and infrared. |
Sensor Life | 2 years under normal conditions. |
Sampling Method | Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH. |
Display | 4 x 20 LCD readout with backlighting. Viewed through window in case top. Displays readings & status of all channels simultaneously. |
Alarms | 2 alarms per channel plus TWA and STEL alarms. Fully adjustable for levels, latching or self reset and silenceable. |
Alarm Method | Buzzer 85dB at 30 cm, dual high intensity LED’s, and blinking display. |
Controls | 6 external push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA /STEL values, battery status and many other features. |
Continuous Operating Hours | 30 hours minimum using alkaline batteries, or 18 hours using Ni-Cads. |
Power Source | Size D batteries, 4 alkaline or Ni-Cad. Charger has alkaline recognition to prevent battery damage if alkalines are charged. |
Operating Temp. & Humidity | -10°C to 40°C (14°F to 104°F), 0 to 95% RH, non-condensing. |
Indication Accuracy | Maximum variance +/- 5% of full scale. |
Response Time | 30 seconds to 90% (for most gases). |
Safety Design | Intrinsically Safe, Class I, Division 1, Groups A, B, C and D. CSA / NRTL & UL Classified (most versions). |
Standard Accesories | Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose (for special toxic gas versions, shorter teflon hose used without probe). |
Optional Accessories | • Datalogging of up to 4 gases (No datalogging possible on 5 or 6 |
gas versions or versions with more than 2 toxic sensors) | |
• Remote alarm | |
• Dilution fitting (50/50) | |
• Ni-Cad batteries | |
• Battery charger, 115 VAC, 220 VAC, or 12 VDC | |
• Continuous operation adapter, 115 VAC or 12 VDC | |
• Extra loud buzzer | |
• Extension probes | |
• Internal hydrophobic filter (strongly recommended) | |
Warranty | One year material and workmanship |
Standard Confined Space Gases | |
Hydrocarbons | 0 - 100% LEL |
Oxygen (O2 ) | 0 - 40% Vol. |
Carbon Monoxide (CO) | 0 - 500 ppm |
Hydrogen Sulfide (H2S) | 0 - 100 ppm |
Super Toxics and Other Gases | |
Ammonia (NH3 ) | 0 - 75 ppm |
Arsine (AsH3 ) | 0 - 1 ppm |
Carbon Dioxide (CO2 ) (I R Sensor) | 0 - 5,000 ppm |
Chlorine (Cl2 ) | 0 - 3 ppm |
Chlorine Dioxide (ClO2 ) | 0 - 1 ppm |
Fluorine (F2 ) | 0 - 5 ppm |
Hydrogen Fluoride (HF) | 0 - 9 ppm |
Hydrogen Chloride (HCl) | 0 - 15 ppm |
Hydrogen Cyanide (HCN) | 0 - 30 ppm |
Methane (CH4 ) (I R Sensor) | 0 - 100% LEL |
Nitrogen Dioxide (NO2 ) | 0 - 15 ppm |
Ozone (O3 ) | 0 - 1 ppm |
Phosphine (PH3 ) | 0 - 1 ppm |
Silane (SiH4 ) | 0 - 15 ppm |
Sulfur Dioxide (SO2 ) | 0 - 30 ppm |
The EAGLE can be provided with up to 6 gas |