MY MENU

เครื่องวัดอัตราการไหลของก๊าซ / ไอน้ำ / ของเหลว

เครื่องวัดอัตราการไหลของก๊าซ

หัวข้อ
AMF900 : Electromagnetic Flowmeter
ผู้เขียน
ผู้ดูแลระบบ
วันที่สร้าง
30/01/2018
สิ่งที่แนบมา0
ดู
1784
เนื้อหา


AMF900 Series

AMF900 Series is a flange type electromagnetic flowmeter ideal for conductive 
liquids. It comes in sizes from 6 to 2000mm. AMF900 is widely used for tap-water, 
waste water, food & beverage pulp &paper and many other industrial fluid. AMF900 Series
electromagnetic flowmeter could be used in compact or separate model with AMC Series 
converter of electromagnetic flowmeter.

FEATURES
• Various liner and electrode satisfy most industrial applications
• Flow Velocity range: 0-12 m/s, precise in low flow applications 
• It comes any flanges such as, ANSI, DIN, JIS... etc
• Excellent for high pressure application
• Protection class: IP68 available; sensor submersible
• FEP Liner is suitable for vacuum tube
• High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading)
• With Forward/Reverse flowrate measurement function

SPECIFICATION
Size:Electrode & Grounding:
6,10,15,20, 25,32,40,50,65,80,100,125Stainless Steel 316L
150,200,250,300,350,400,450,500,600Hastelloy B
700,800,900,1000,1200,1400,1600Hastelloy C
1800,2000 mmTitanium
Measuring Range:Tantalum
Velocity   0 - 0.25 m/s min.Platinum
                0 - 12  m/s max.Tungsten Carbide
Material:Cable Entry:
Measuring TubeStandard :PG11  Option:1/2"NPTF
Stainless Steel 304Ambient Temperature:
Flange
-25 to +60 oC
Carbon Steel (Standard)Process Connection:
Stainless Steel 304 (Option)Flange 
Stainless Steel 316, 316L (Option)Flange Type:
Coil HousingJIS 10K / JIS 20K / JIS 40K
Carbon Steel (Standard)ANSI 150# / ANSI 300# / ANSI 600#
Stainless Steel 304 (Option)DIN PN 10 / PN 16 / PN25 / PN 40
Stainless Steel 316,316L (Option)Grounding Resistance:
Liner:Must be  less than 10 
Polyurethane (25-600 mm)Accuracy:
Neoprene (50-2000 mm)+/-0.4% read-out values (Velocity >=0.5 m/s)
FEP (6-300 mm)+/-0.0025 m/s (Velocity < 0.5 m/s)
PTFE (25-800 mm)+/-0.2% read-out values
PFA (6-300 mm)(Suitable for AMC3100 converter only)
Protection Class:Temperature:
Junction box IP67, Body IP68
-10 ~ +60oC (Polyurethane, PU)
IP 68 (Submersible)
-20 ~ +70oC (Neoprene)
Conductivity:
-40 ~ +180oC (FEP)
More than 5 uS/cm
-40 ~ +180oC (PTFE/PFA)
Explosion Proof:Max. Pressure:
Exd(ib)ibqIIBT5 (with AMC3100/AMC4000 only)350 Kg/cm2