เครื่องวัดอัตราการไหลของก๊าซ / ไอน้ำ / ของเหลว
เครื่องวัดอัตราการไหลของก๊าซ / ไอน้ำ / ของเหลว
เครื่องวัดอัตราการไหลของก๊าซ
18
AUF200 : Ultrasonic Flowmeter
AUF200 Series
AUF200 Series measure flow or energy of water running in heating/cooling pipe by temperature sensor based on ultrasonic flowmeter. It's simple, easy to install and battery powered, no need of external power. It can display flow rate, total flow, total heat, total cool, heat power and supply/return temperature etc..
FEATURES
● Display flow rate, total flow, heating and cooling energy ● 3.6V battery power, continuous working for 6 years ● Auto turn off LCD if no operation within 3 minutes, saving power ● Supply or return alternatively for mounting ● Displayer 270o rotational ● Medium temperature up to 105 oC, DT 0-80 oC ● Threaded connection, easy for installation ● M-BUS communication, easy for remote control and reading ● Response time<15s
SPECIFICATION
Measuring Principle:Velocity:Ultrasonic, Time difference W path0.01 ~ 5 m/sSize:Connection:15mm, 20mm, 25mm, 32mm, 40mmThreadMaterial:Working Pressure:Sensor25 Kg/cm2 MaximumStainless Steel 304Mounting Position:CouplingSupply or Return pipeBrassDisplayer:Ball ValveCompact, 270o rotationalBrassAmbient Temp.:Display Housing-10 ~ +55 o CPCAmbient Humidity:Turndown Ratio:<=95% RH50:1 ~100:1Power Supply:Accuracy:Battery Power+/-2% Qt ~ QmaxBattery Life:Repeatability:> 6 years (3800mA)+/-0.3% of readingRecord Cycle:Sensor Type:18 monthsPT1000 2 wire, Class BRecord Data:Medium Temp. Range:Monthly Flow & Energy Totalizer0 ~ +105 o CCommunication:Temp. Resolution:M-BUS (optional)0.1 o CKeyboard:Temp. Difference:One touch-control key (read only)3 - 80 o CResponse Time:Temp. Error:<15 Second< 0.1 o CDimensions:Temp. Cable Length:Page 31.5mProtection Class:Display:IP652 lines, LCD Communicator:TemperatureM-BUS private communicatoro C (Supply and Return), TAccessory:TotalizerCoupling x 1 PairM3, KW or GJ , Hour, 8 DigitBall Valve with temperature sensor holeFlow RateM-BUS private communicatorM3/h, 4 digit Energy KW.h (Standard), GJ (Optional) Pressure Drop: Less than 0.2 Kg/cm2 (at Qn / Q3) ผู้ดูแลระบบ 06/02/2018
AUF200 Series
AUF200 Series measure flow or energy of water running in heating/cooling pipe by temperature sensor based on ultrasonic flowmeter. It's simple, easy to install and battery powered, no need of external power. It can display flow rate, total flow, total heat, total cool, heat power and supply/return temperature etc..
FEATURES
● Display flow rate, total flow, heating and cooling energy ● 3.6V battery power, continuous working for 6 years ● Auto turn off LCD if no operation within 3 minutes, saving power ● Supply or return alternatively for mounting ● Displayer 270o rotational ● Medium temperature up to 105 oC, DT 0-80 oC ● Threaded connection, easy for installation ● M-BUS communication, easy for remote control and reading ● Response time<15s
SPECIFICATION
Measuring Principle:Velocity:Ultrasonic, Time difference W path0.01 ~ 5 m/sSize:Connection:15mm, 20mm, 25mm, 32mm, 40mmThreadMaterial:Working Pressure:Sensor25 Kg/cm2 MaximumStainless Steel 304Mounting Position:CouplingSupply or Return pipeBrassDisplayer:Ball ValveCompact, 270o rotationalBrassAmbient Temp.:Display Housing-10 ~ +55 o CPCAmbient Humidity:Turndown Ratio:<=95% RH50:1 ~100:1Power Supply:Accuracy:Battery Power+/-2% Qt ~ QmaxBattery Life:Repeatability:> 6 years (3800mA)+/-0.3% of readingRecord Cycle:Sensor Type:18 monthsPT1000 2 wire, Class BRecord Data:Medium Temp. Range:Monthly Flow & Energy Totalizer0 ~ +105 o CCommunication:Temp. Resolution:M-BUS (optional)0.1 o CKeyboard:Temp. Difference:One touch-control key (read only)3 - 80 o CResponse Time:Temp. Error:<15 Second< 0.1 o CDimensions:Temp. Cable Length:Page 31.5mProtection Class:Display:IP652 lines, LCD Communicator:TemperatureM-BUS private communicatoro C (Supply and Return), TAccessory:TotalizerCoupling x 1 PairM3, KW or GJ , Hour, 8 DigitBall Valve with temperature sensor holeFlow RateM-BUS private communicatorM3/h, 4 digit Energy KW.h (Standard), GJ (Optional) Pressure Drop: Less than 0.2 Kg/cm2 (at Qn / Q3) ผู้ดูแลระบบ 06/02/2018
17
ACF6000 : Coriolis Mass Flowmeter
ACF6000 Series
ACF6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement.The ACF6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.
FEATURES
● Can be programmed by infrared light sensor without opening cover ● High turndown ratio of flow rate ● It comes any flanges such as ANSI, DIN, JIS... etc ● Excellent for high pressure application ● Simple for installation, commission and maintenance ● Self-diagnostic capabilities, cable faults, pipe vibration ● High accuracy of +/-0.2% of reading (or +/-0.1% of reading) ● With forward / reverse flow rate measurement function
SPECIFICATION
Sensor Type:Display:C tube (10-40mm) / U tube (50-150mm)2 lines LCD with illuminationSize:Flow Rate Unit10mm ~ 200 mm (3/8" ~ 8")g/s, Kg/min, kg/Hr, T/Hr, 5 DigitFlow Range:Density Unit0 - 1000 Kg/Hr ~ 0 - 1106000 Kg/HrKg/m3, g/cc, 5 DigitAccuracy:Totalizer Unit+/-0.2% +/-ZS of reading (Standard)g, Kg, Ton, L, M3, 11 Digits+/-0.1% +/-ZS of reading (Optional)TemperatureRepeatability:oC, oF, 4 Digits+/-0.03% +/-ZS of readingKeypad:Density Range:Infrared light Sensor,200 - 2300 Kg/M3 (0.2 - 2.3 g/cm3)can be programmed withoutAccuracyOpening the cover+/-0.002 g/cm3Turndown Ratio:Temperature Range:20 : 1-40 oC ~ +125 oC (Standard)Damping:-40 oC ~ +250 oC (Optional, Separate Only)0.01 To 1.0 SecondsMaterial:Low Flow Cutoff:Wetted Parts0.0% ~ 9.0%Stainless Steel 316LCommunication:FlangeRS485 (Modbus Protocol) (Standard)Stainless Steel 316LHart Signal (Optional)Sensor HousingCurrent Output:Stainless Steel 3044-20 mA (Isolated)Junction BoxLoadAluminum Alloy (Epoxy Paint)Max. 750 Process Connection:Output UnitFlange Mass / Volume / Density / TemperatureFlange Type:Pulse (Alarm) Output:JIS 10K / JIS 20K / JIS 40KOpen CollectorANSI 150# / ANSI 300# / ANSI 600#RatingDIN PN 10 / PN 16 / PN25 / PN 403-30Vdc, 50mA Max.Protection Class:Power Supply:IP 6790-260 VAC, 50/60 Hz or 24 VDC +/-10%Explosion Proof Exde (ib) IIC T6 (Optional)Power Consumption:Installation:30 - 40 W (Depend on sensor size)Compact or SeparateCable Entry:Signal Cable Length:Sensor to Converter- 3/4" G10M - 100MSignal output / Power supply- M20 Ambient Temperature: -40 oC to +60 oC Max. Pressure: 63 Kg/cm2 ผู้ดูแลระบบ 06/02/2018
ACF6000 Series
ACF6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement.The ACF6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.
FEATURES
● Can be programmed by infrared light sensor without opening cover ● High turndown ratio of flow rate ● It comes any flanges such as ANSI, DIN, JIS... etc ● Excellent for high pressure application ● Simple for installation, commission and maintenance ● Self-diagnostic capabilities, cable faults, pipe vibration ● High accuracy of +/-0.2% of reading (or +/-0.1% of reading) ● With forward / reverse flow rate measurement function
SPECIFICATION
Sensor Type:Display:C tube (10-40mm) / U tube (50-150mm)2 lines LCD with illuminationSize:Flow Rate Unit10mm ~ 200 mm (3/8" ~ 8")g/s, Kg/min, kg/Hr, T/Hr, 5 DigitFlow Range:Density Unit0 - 1000 Kg/Hr ~ 0 - 1106000 Kg/HrKg/m3, g/cc, 5 DigitAccuracy:Totalizer Unit+/-0.2% +/-ZS of reading (Standard)g, Kg, Ton, L, M3, 11 Digits+/-0.1% +/-ZS of reading (Optional)TemperatureRepeatability:oC, oF, 4 Digits+/-0.03% +/-ZS of readingKeypad:Density Range:Infrared light Sensor,200 - 2300 Kg/M3 (0.2 - 2.3 g/cm3)can be programmed withoutAccuracyOpening the cover+/-0.002 g/cm3Turndown Ratio:Temperature Range:20 : 1-40 oC ~ +125 oC (Standard)Damping:-40 oC ~ +250 oC (Optional, Separate Only)0.01 To 1.0 SecondsMaterial:Low Flow Cutoff:Wetted Parts0.0% ~ 9.0%Stainless Steel 316LCommunication:FlangeRS485 (Modbus Protocol) (Standard)Stainless Steel 316LHart Signal (Optional)Sensor HousingCurrent Output:Stainless Steel 3044-20 mA (Isolated)Junction BoxLoadAluminum Alloy (Epoxy Paint)Max. 750 Process Connection:Output UnitFlange Mass / Volume / Density / TemperatureFlange Type:Pulse (Alarm) Output:JIS 10K / JIS 20K / JIS 40KOpen CollectorANSI 150# / ANSI 300# / ANSI 600#RatingDIN PN 10 / PN 16 / PN25 / PN 403-30Vdc, 50mA Max.Protection Class:Power Supply:IP 6790-260 VAC, 50/60 Hz or 24 VDC +/-10%Explosion Proof Exde (ib) IIC T6 (Optional)Power Consumption:Installation:30 - 40 W (Depend on sensor size)Compact or SeparateCable Entry:Signal Cable Length:Sensor to Converter- 3/4" G10M - 100MSignal output / Power supply- M20 Ambient Temperature: -40 oC to +60 oC Max. Pressure: 63 Kg/cm2 ผู้ดูแลระบบ 06/02/2018
16
AFC365 : Flow Computer
AFC365 Series
AFC365 Series Flow Computer is a microprocessor-based instrument designed to measure compensated flow in industrial environment.The AFC365 incorporates the Ideal Gas / Steam / Natural Gas compensation.The Backlit LCD display simplifies programming and clearly indicates all parameters as well as engineering units.
FEATURES
● DIN Size (96mm*96mm), 320*240 Pixels, 4-line LCD display ● Built-in 8MB memory, applicable to long-term data record ● Common input signal: mA, RTD, Frequency etc. ● High Accuracy +/-0.1% of Reading ● 4-20mA / Relay / RS485 output ● Ideal Gas/ General Gas / Steam / Energy formula ● 24VDC Aux. power supply available for 2 wires system ● Fascia Sealing for IP65(NEMA 4X) water tight ● Hourly / Daily / Monthly / Yearly history data record
SPECIFICATION
Number of Inputs:Display:3 Channels3.5" Mono-screen LCD with BacklitFlow Function:Response Time:Input100 ms4-20 mA / Frequency (0-10 KHz)Keypad:Display6 keys for programming and display5 digits flowrate with decimal pointcontrol13 digits totalizer with decimal pointEngineer Unit:Accuracy21 different engineering units+/-0.1% of readingParameter Protection:Temperature Function:2 Password entries (6 Digits) forone or two point (Energy calculator)Supplier and UserInput:Logging Rate:PT100 / 4-20 mA1 minutes ~ 60 minutes Per DataDisplayRecording Capability:4 digits temperature value with decimal point30 days (1 Data/minutes)Accuracy1800 days (1 Data/Hour)+/-0.1 oCStorage Memory:Pressure Function:8 MB (on board)InputRecycling Mode:4-20 mA Newest data overwrites oldest dataDisplayProtection Class:5 digits pressure value with decimal pointNEMA4 / IP65 (Fascia sealing)AccuracyWeight:+/-0.1% of reading0.5 Kg MaximumCalculation Function:Dimensions:Ideal Gas, Temperature & Pressure Comp.96mm (W) * 96 mm (H) *150 mm (D)General Gases, Temp & Pressure Comp.Ambient Temperature:Natural Gas, NX-192 Formula-10 ~ +60 oCSaturated Steam, Superheated SteamAmbient Humidity:Liquid Mass, Density calculation10% ~ 85%RH (5 ~ 40 oC)Alarm Types:Power Supply:High & Low alarm, Incr. & Decr. alarm85-260VAC, 50/60HzAux. Power Output:Vibration Test:12VDC / 24VDC,100mA for Flow Transmitter10~60Hz ,10 m/S2 for 3 hours24VDC, 100mA for Temperature TransmitterPower Consumption:24VDC ,100mA for Pressure Transmitter¡Ü10 WOutput:Communication:4-20 mA, Load 750 * 1 pointRS485 (MODBUS Protocol)Relay, 3A/250V * 1 pointParameter Storage: Operation parameters are stored by EEPROM for more than 10 years ผู้ดูแลระบบ 06/02/2018
AFC365 Series Flow Computer is a microprocessor-based instrument designed to measure compensated flow in industrial environment.The AFC365 incorporates the Ideal Gas / Steam / Natural Gas compensation.The Backlit LCD display simplifies programming and clearly indicates all parameters as well as engineering units.
FEATURES
● DIN Size (96mm*96mm), 320*240 Pixels, 4-line LCD display ● Built-in 8MB memory, applicable to long-term data record ● Common input signal: mA, RTD, Frequency etc. ● High Accuracy +/-0.1% of Reading ● 4-20mA / Relay / RS485 output ● Ideal Gas/ General Gas / Steam / Energy formula ● 24VDC Aux. power supply available for 2 wires system ● Fascia Sealing for IP65(NEMA 4X) water tight ● Hourly / Daily / Monthly / Yearly history data record
SPECIFICATION
Number of Inputs:Display:3 Channels3.5" Mono-screen LCD with BacklitFlow Function:Response Time:Input100 ms4-20 mA / Frequency (0-10 KHz)Keypad:Display6 keys for programming and display5 digits flowrate with decimal pointcontrol13 digits totalizer with decimal pointEngineer Unit:Accuracy21 different engineering units+/-0.1% of readingParameter Protection:Temperature Function:2 Password entries (6 Digits) forone or two point (Energy calculator)Supplier and UserInput:Logging Rate:PT100 / 4-20 mA1 minutes ~ 60 minutes Per DataDisplayRecording Capability:4 digits temperature value with decimal point30 days (1 Data/minutes)Accuracy1800 days (1 Data/Hour)+/-0.1 oCStorage Memory:Pressure Function:8 MB (on board)InputRecycling Mode:4-20 mA Newest data overwrites oldest dataDisplayProtection Class:5 digits pressure value with decimal pointNEMA4 / IP65 (Fascia sealing)AccuracyWeight:+/-0.1% of reading0.5 Kg MaximumCalculation Function:Dimensions:Ideal Gas, Temperature & Pressure Comp.96mm (W) * 96 mm (H) *150 mm (D)General Gases, Temp & Pressure Comp.Ambient Temperature:Natural Gas, NX-192 Formula-10 ~ +60 oCSaturated Steam, Superheated SteamAmbient Humidity:Liquid Mass, Density calculation10% ~ 85%RH (5 ~ 40 oC)Alarm Types:Power Supply:High & Low alarm, Incr. & Decr. alarm85-260VAC, 50/60HzAux. Power Output:Vibration Test:12VDC / 24VDC,100mA for Flow Transmitter10~60Hz ,10 m/S2 for 3 hours24VDC, 100mA for Temperature TransmitterPower Consumption:24VDC ,100mA for Pressure Transmitter¡Ü10 WOutput:Communication:4-20 mA, Load 750 * 1 pointRS485 (MODBUS Protocol)Relay, 3A/250V * 1 pointParameter Storage: Operation parameters are stored by EEPROM for more than 10 years ผู้ดูแลระบบ 06/02/2018
15
AMF301 Series
AMF301 Series
AMF301 Series is a threaded type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 4 to 25 mm.The AMF301 is widely used for tap-water, waste water, food & beverage, pulp & paper and many other industrial fluid.AMF301 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES
● Light and compact version● Flow velocity range: 0-12 m/s, precisely in low flow applications ● Interface thread piping● FEP Liner suitable for vacuum tube● High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)● With Forward / Reverse flowrate measurement function
SPECIFICATION
Size:Cable Entry:4, 6, 10, 15, 25 mmStandard :PG11 Option:1/2"NPTFMeasuring Range:Ambient Temperature:Velocity 0-0.25 m/s min.-25 to +60 oC 0-12 m/s max.Process Connection:Material:Screw male thread (BSP) Tube & ConnectionGrounding Resistance:Stainless Steel 304Must be less than 10ΩCoil HousingAccuracy:Carbon Steel (Standard)+/-0.4% of reading (Velocity>=0.5 m/s)Liner+/-0.2% of readingFEP(Suitable for AMC3200/3200E converter )Electrode+/-0.0025 m/s (Velocity< 0.5 m/s)Stainless Steel 316L (4mm~25mm)Temperature:Titanium (4mm~25mm)CompactHastelloy B (4mm~25mm)-10 ~ +80 oCHastelloy C (4mm~25mm)SeparateTantalum (4mm~25mm)-20 ~ +120 oCPlatinum (25mm)Max. Pressure:Flow Range:16 Kg/cm24 mmExplosion Proof:0 - 11.3 L/Hr ~ 0 - 543 L/HrExd(ib)ibqIIBT56mm(with AMC3200 only)0 - 25 L/Hr ~ 0 - 1221 L/HrProtection Class:10 mmIP 670 - 71 L/Hr ~ 0 - 3393 L/HrConductivity:15 mmMore than 5 uS/cm0 - 159 L/Hr ~ 0 - 7634 L/Hr25 mm0 - 442 L/Hr ~ 0 - 21205 L/Hr
ผู้ดูแลระบบ 06/02/2018
AMF301 Series
AMF301 Series is a threaded type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 4 to 25 mm.The AMF301 is widely used for tap-water, waste water, food & beverage, pulp & paper and many other industrial fluid.AMF301 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES
● Light and compact version● Flow velocity range: 0-12 m/s, precisely in low flow applications ● Interface thread piping● FEP Liner suitable for vacuum tube● High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)● With Forward / Reverse flowrate measurement function
SPECIFICATION
Size:Cable Entry:4, 6, 10, 15, 25 mmStandard :PG11 Option:1/2"NPTFMeasuring Range:Ambient Temperature:Velocity 0-0.25 m/s min.-25 to +60 oC 0-12 m/s max.Process Connection:Material:Screw male thread (BSP) Tube & ConnectionGrounding Resistance:Stainless Steel 304Must be less than 10ΩCoil HousingAccuracy:Carbon Steel (Standard)+/-0.4% of reading (Velocity>=0.5 m/s)Liner+/-0.2% of readingFEP(Suitable for AMC3200/3200E converter )Electrode+/-0.0025 m/s (Velocity< 0.5 m/s)Stainless Steel 316L (4mm~25mm)Temperature:Titanium (4mm~25mm)CompactHastelloy B (4mm~25mm)-10 ~ +80 oCHastelloy C (4mm~25mm)SeparateTantalum (4mm~25mm)-20 ~ +120 oCPlatinum (25mm)Max. Pressure:Flow Range:16 Kg/cm24 mmExplosion Proof:0 - 11.3 L/Hr ~ 0 - 543 L/HrExd(ib)ibqIIBT56mm(with AMC3200 only)0 - 25 L/Hr ~ 0 - 1221 L/HrProtection Class:10 mmIP 670 - 71 L/Hr ~ 0 - 3393 L/HrConductivity:15 mmMore than 5 uS/cm0 - 159 L/Hr ~ 0 - 7634 L/Hr25 mm0 - 442 L/Hr ~ 0 - 21205 L/Hr
ผู้ดูแลระบบ 06/02/2018
14
AUT8500 : Ultrasonic Thickness Gauge
FEATURES
● Auto calibration to assure accuracy ● Low battery indication ● Preset or store more than ten sound velocity and thickness measurement data ● Auto power off if no operation within two minutes ● With a given thickness to measure the sound velocity ● Coupling status indication ● High / Low thickness buzzer alarm
SPECIFICATION
Model:Model:AUT8500AAUT8500BMeasuring Range:Measuring Range:1.2 ~ 225.0 mm1.00 ~ 300.0 mm (1/25" ~ 12")ResolutionResolution0.1mm0.01mmMin. limit for tube:Min. limit for steel tube:20 * 3.0 mm (f10 Transducer)15 * 2.0 mm (f 6 Transducer)Accuracy:20 * 3.0 mm (f 10 Transducer)+/-1% of Reading +/-0.1mmAccuracy:Engineer unit:+/-0.8% of Reading +/-0.05mmmmEngineer unit:Sound Velocity Range:mm / Inch1000 ~ 9999 m/sSound Velocity Range:Accuracy of Velocity:1000 ~ 9999 m/s+/-1% of Reading ( Thickness < 20mm )Accuracy of Velocity:+/-5% of Reading ( Thickness > 20mm )+/-1% of Reading ( Thickness < 20mm )Operating Temp.:+/-5% of Reading ( Thickness > 20mm )-20 to +60 oCAlarm Setting:Battery life:High / Low Thickness Alarm With Buzzer15 to 20 HoursOperating Temp.:Power Supply:-20 to +60 oC1.5V AAA Battery * 3 pcsBattery life:Power Consumption:30 to 35 hours<0.54 W (with back light on)Power Supply:Standard Package:1.5V AAA Battery * 3 pcsUltrasonic Thickness GaugePower Consumption:10 Transducer ( 5MHz )<0.16W (with back light on)Ultrasonic CouplantStandard Package:Sample BlockUltrasonic Thickness GaugeLeather Case Cover10 Transducer ( 5MHz )Carrying Case6 Transducer ( 5MHz )
Ultrasonic Couplant
Sample Block
Leather Case Cover
Carrying Case ผู้ดูแลระบบ 06/02/2018
FEATURES
● Auto calibration to assure accuracy ● Low battery indication ● Preset or store more than ten sound velocity and thickness measurement data ● Auto power off if no operation within two minutes ● With a given thickness to measure the sound velocity ● Coupling status indication ● High / Low thickness buzzer alarm
SPECIFICATION
Model:Model:AUT8500AAUT8500BMeasuring Range:Measuring Range:1.2 ~ 225.0 mm1.00 ~ 300.0 mm (1/25" ~ 12")ResolutionResolution0.1mm0.01mmMin. limit for tube:Min. limit for steel tube:20 * 3.0 mm (f10 Transducer)15 * 2.0 mm (f 6 Transducer)Accuracy:20 * 3.0 mm (f 10 Transducer)+/-1% of Reading +/-0.1mmAccuracy:Engineer unit:+/-0.8% of Reading +/-0.05mmmmEngineer unit:Sound Velocity Range:mm / Inch1000 ~ 9999 m/sSound Velocity Range:Accuracy of Velocity:1000 ~ 9999 m/s+/-1% of Reading ( Thickness < 20mm )Accuracy of Velocity:+/-5% of Reading ( Thickness > 20mm )+/-1% of Reading ( Thickness < 20mm )Operating Temp.:+/-5% of Reading ( Thickness > 20mm )-20 to +60 oCAlarm Setting:Battery life:High / Low Thickness Alarm With Buzzer15 to 20 HoursOperating Temp.:Power Supply:-20 to +60 oC1.5V AAA Battery * 3 pcsBattery life:Power Consumption:30 to 35 hours<0.54 W (with back light on)Power Supply:Standard Package:1.5V AAA Battery * 3 pcsUltrasonic Thickness GaugePower Consumption:10 Transducer ( 5MHz )<0.16W (with back light on)Ultrasonic CouplantStandard Package:Sample BlockUltrasonic Thickness GaugeLeather Case Cover10 Transducer ( 5MHz )Carrying Case6 Transducer ( 5MHz )
Ultrasonic Couplant
Sample Block
Leather Case Cover
Carrying Case ผู้ดูแลระบบ 06/02/2018
13
AMF100 : Insertion Electromagnetic Flowmeter
FEATURES
● Light and compact version ● Measuring range up to 12 m/s ● Suitable for permanent or temporary installation ● Price virtually independent of pipe diameter ● Hot-tap into pressurised pipe ● Good accuracy over wide operating flow range ● With Forward/Reverse flow rate measurement function ● Stable calibration and reliable operation
SPECIFICATION
Size:Cable Entry:150 , 200 , 250 , 300 , 350 , 400 , 450Standard: PG11 Option:1/2"NPTF500 , 600 , 700 ..... 6000 mmGrounding Resistance:Measuring Range:Must be less than 10 Velocity 0-0.25 m/s min.Accuracy: 0-12 m/s max.+/-2% of reading (Velocity >=0.5 m/s)Material:+/-0.8% of Full Scale (F.S.>2 m/s)Protection tube+/-0.01 m/s (Velocity < 0.5 m/s)Stainless Steel 316Repeatability:Screw+/-0.4% of readingStainless Steel 316Process Temperature:Electrode-10 ~ 80 oCStainless Steel 316L Ambient Temperature:Cap-25 to +70 oCPTFEMax. Pressure:Ball Valve10 Kg/cm2Stainless Steel 316(Optional)Conductivity:Hot-Tap tool / KitMore than 10 uS/cmStainless Steel 304(Optional)Weight:Mounting:3 ~ 10 KgCompact or separateCoil Resistance:Process Connection:70 - 98 ThreadedSensor Diameter:Threaded, 2" BSP Female45 mmFlangeSensor Length:Flange, JIS / ANSI / DIN310mm (for 150 ~ 600mm pipe ID)Installation:510mm(for 600 ~ 2000mm pipe ID)Direct insert to the pipe800mm(for 2000 ~ 4000mm pipe ID)Insert with Ball Value1100mm (for 4000 ~ 6000mm pipe ID)Hot-Tap into pressurised pipe
Protection Class:
IP 67
IP 68 (Submersible)
Explosion Proof:
Exd(ib)ibqIIBT5 (with AMC3100 only) ผู้ดูแลระบบ 06/02/2018
FEATURES
● Light and compact version ● Measuring range up to 12 m/s ● Suitable for permanent or temporary installation ● Price virtually independent of pipe diameter ● Hot-tap into pressurised pipe ● Good accuracy over wide operating flow range ● With Forward/Reverse flow rate measurement function ● Stable calibration and reliable operation
SPECIFICATION
Size:Cable Entry:150 , 200 , 250 , 300 , 350 , 400 , 450Standard: PG11 Option:1/2"NPTF500 , 600 , 700 ..... 6000 mmGrounding Resistance:Measuring Range:Must be less than 10 Velocity 0-0.25 m/s min.Accuracy: 0-12 m/s max.+/-2% of reading (Velocity >=0.5 m/s)Material:+/-0.8% of Full Scale (F.S.>2 m/s)Protection tube+/-0.01 m/s (Velocity < 0.5 m/s)Stainless Steel 316Repeatability:Screw+/-0.4% of readingStainless Steel 316Process Temperature:Electrode-10 ~ 80 oCStainless Steel 316L Ambient Temperature:Cap-25 to +70 oCPTFEMax. Pressure:Ball Valve10 Kg/cm2Stainless Steel 316(Optional)Conductivity:Hot-Tap tool / KitMore than 10 uS/cmStainless Steel 304(Optional)Weight:Mounting:3 ~ 10 KgCompact or separateCoil Resistance:Process Connection:70 - 98 ThreadedSensor Diameter:Threaded, 2" BSP Female45 mmFlangeSensor Length:Flange, JIS / ANSI / DIN310mm (for 150 ~ 600mm pipe ID)Installation:510mm(for 600 ~ 2000mm pipe ID)Direct insert to the pipe800mm(for 2000 ~ 4000mm pipe ID)Insert with Ball Value1100mm (for 4000 ~ 6000mm pipe ID)Hot-Tap into pressurised pipe
Protection Class:
IP 67
IP 68 (Submersible)
Explosion Proof:
Exd(ib)ibqIIBT5 (with AMC3100 only) ผู้ดูแลระบบ 06/02/2018
12
AMC4000 : Converter
AMC4000 Series
The Aliamag AMC4000 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.
FEATURES
● Battery life 2~3 years in normal working condition ● Accuracy of +/-0.3% value of reading ● Bi-directional flow measurement, current and pulse output ● 3 lines of LCD display flowrate and totalizer ● Records up to 99 power on/off time ● IP67 / IP68 protection class
SPECIFICATION
Excitation:Low Flow Cutoff:DC pulsed0 ~ 9.9 %Display:Self Diagnosis:3 lines of LCDThe following error messagePage 1/ Line 1 are displayed if failure occurs5-digit flowrate- Coil failurePage 1/ Line 2- Power failure11-digit forward totalizer- Overranged outputPage 1/ Line 3- Internal errorBattery status, flow velocity- OverflowPage 2/ Line 1- Empty pipe11-digit totalizerCable Entry:Page 2/ Line 2Standard :PG11 Option:1/2"NPTF11-digit reverse totalizerProtection Class:Page 2/ Line 3IP 67Display instantaneous velocityIP 68 (Submersible)Page 3Explosion Proof, Exd(ib)ibqIIBT5AlarmAmbient Temp.:Flow Unit:-25 ~ +65 oCM3/Hr, M3/min, M3/sec, L/Hr, L/minHousing Material:GPH, GPM, GPS, ML/H, ML/m, ML/SAluminum alloyTotalizer Unit:Power Supply:M3, Gallon, Liter, ML3.6V battery, Size DMeasuring Range:Battery Life:Min. 0 ~ 0.15 m/s2~3 yearsMax. 0 ~ 15.0 m/sDetermined by size & functionAccuracy:Communication Protocol:+/-0.3% of reading (Velocity >=0.5 m/s)RS 485 (MODBUS protocol)+/-0.0015 m/s (Velocity£¼0.5 m/s)Weight:Repeatability:2.0 Kg (Compact)+/-0.05% of reading4.3 Kg (Separate)Pulse Output:Mounting:Open collectorWall mountingLoadBracket on 2" pipe3 ~ 30 Vdc, max. 20 mACompact version ( Installed on sensor)Pulse Rate: 1)Scaled pulse ( Liter/Pulse, other) 2)Frequency: 1~5000 Hz Keypad: 4 control keys to change parameters and switch display interface Damping: 0.1~99.9s Data Storage: Operation parameters and totalizer are stored by EEPROM for more than 10 years ผู้ดูแลระบบ 05/02/2018
AMC4000 Series
The Aliamag AMC4000 series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.
FEATURES
● Battery life 2~3 years in normal working condition ● Accuracy of +/-0.3% value of reading ● Bi-directional flow measurement, current and pulse output ● 3 lines of LCD display flowrate and totalizer ● Records up to 99 power on/off time ● IP67 / IP68 protection class
SPECIFICATION
Excitation:Low Flow Cutoff:DC pulsed0 ~ 9.9 %Display:Self Diagnosis:3 lines of LCDThe following error messagePage 1/ Line 1 are displayed if failure occurs5-digit flowrate- Coil failurePage 1/ Line 2- Power failure11-digit forward totalizer- Overranged outputPage 1/ Line 3- Internal errorBattery status, flow velocity- OverflowPage 2/ Line 1- Empty pipe11-digit totalizerCable Entry:Page 2/ Line 2Standard :PG11 Option:1/2"NPTF11-digit reverse totalizerProtection Class:Page 2/ Line 3IP 67Display instantaneous velocityIP 68 (Submersible)Page 3Explosion Proof, Exd(ib)ibqIIBT5AlarmAmbient Temp.:Flow Unit:-25 ~ +65 oCM3/Hr, M3/min, M3/sec, L/Hr, L/minHousing Material:GPH, GPM, GPS, ML/H, ML/m, ML/SAluminum alloyTotalizer Unit:Power Supply:M3, Gallon, Liter, ML3.6V battery, Size DMeasuring Range:Battery Life:Min. 0 ~ 0.15 m/s2~3 yearsMax. 0 ~ 15.0 m/sDetermined by size & functionAccuracy:Communication Protocol:+/-0.3% of reading (Velocity >=0.5 m/s)RS 485 (MODBUS protocol)+/-0.0015 m/s (Velocity£¼0.5 m/s)Weight:Repeatability:2.0 Kg (Compact)+/-0.05% of reading4.3 Kg (Separate)Pulse Output:Mounting:Open collectorWall mountingLoadBracket on 2" pipe3 ~ 30 Vdc, max. 20 mACompact version ( Installed on sensor)Pulse Rate: 1)Scaled pulse ( Liter/Pulse, other) 2)Frequency: 1~5000 Hz Keypad: 4 control keys to change parameters and switch display interface Damping: 0.1~99.9s Data Storage: Operation parameters and totalizer are stored by EEPROM for more than 10 years ผู้ดูแลระบบ 05/02/2018
11
ARC900 : Paperless Recorder
FEATURES
● DIN Size(144mm*144mm), 320*240Pixels,TFT truecolor(LCD) ● 128MB memory installed inside, applied to long terms data record ● Common input signal, mA, Include VDC, T/C, RTD,Hz..etc ● High Accuracy +/-0.15% of Reading ● Maximum to 12 points Relay, 4 point 4-20mA output and 24VDC output ● Maximum can receive 16 channels input signal ● Could selected 24VDC Aux. Power supply for 2 wires system ● It can Display/Record single point,Multi-point,Trend,Totalizer,Bargraph ● The recorded data could be stored in USB memory & SD memory card and take out to computer make soft analysis
SPECIFICATION
Number of Inputs:Display:1-16 Channels5.6" color-screen LCDInputs:Trend & BargraphT/C (K, S, B, E, J, N, T, R,N, etc.)Vertical / Horizontal / LandscapeRTD,CU50, CU53,BA1, BA2DigitalDCA(4-20 mA, 0-10 mA, 0-20 mA)4-1/2 digits programmableDCV( 0-5V, 1-5V ,0-10V, 20mV, 100mV)Engineer unitFrequency(1Hz ~ 5KHz)66 Engineering unitsResistance(0-175 W, 0-400 W)Parameter ProtectAccuracy:Password entry(6 Digits)+/-0.15% of SpanLogging Rate:Response Time:1 Seconds ~ 1800 Seconds Per Pen50 msRecording Capability:Alarm Types:120 Hours(16 Points, 1 Data/Second)High & Low alarm, Incr. & Decr. alarm18936 Years(1 Point, 1 Data/Hour)Output:PC software:4-20 mA *4 points Maximum, Load:800WCompatible with Windows 2000/XP/VistaRelay, 3A/250V * 12 points MaximumDisplay24VDC, 65 mA *4 points MaximumTrend, Digital, Circular, Alarm, BargraphDigit Input:Totalizer2 Points MaximumConvert functionStorage Memory:Can be save as excel files128 MB(on board)Enclosure:Recycling Mode:NEMA 3 / IP 54Newest Data over-writes to oldest dataWeight:Recording Data Shift:2.6 Kg maximumUSB memory(2GB) / SD Card(2GB)Dimensions:Display update Rate:144 mm (W) * 144 mm (H) * 219 mm (D)1 SecondAmbient Temperature:Keyboard:-10 to +60 oC6 Keys (Page,Left,Right,Up,Down,Enter) Ambient Humidity:for programming and display control10% to 85%RH (at 5 to 40 oC )Parameter Storage:Power Supply:Operation Parameters are stored by 85-260VAC, 50/60HzEEPROM for more then 10 yearsVibration Test: 10~60Hz ,10m/S2 for 3 hours Power Consumption: <=20 W Communication: RS232 / RS485 (MODBUS Protocol) ผู้ดูแลระบบ 05/02/2018
FEATURES
● DIN Size(144mm*144mm), 320*240Pixels,TFT truecolor(LCD) ● 128MB memory installed inside, applied to long terms data record ● Common input signal, mA, Include VDC, T/C, RTD,Hz..etc ● High Accuracy +/-0.15% of Reading ● Maximum to 12 points Relay, 4 point 4-20mA output and 24VDC output ● Maximum can receive 16 channels input signal ● Could selected 24VDC Aux. Power supply for 2 wires system ● It can Display/Record single point,Multi-point,Trend,Totalizer,Bargraph ● The recorded data could be stored in USB memory & SD memory card and take out to computer make soft analysis
SPECIFICATION
Number of Inputs:Display:1-16 Channels5.6" color-screen LCDInputs:Trend & BargraphT/C (K, S, B, E, J, N, T, R,N, etc.)Vertical / Horizontal / LandscapeRTD,CU50, CU53,BA1, BA2DigitalDCA(4-20 mA, 0-10 mA, 0-20 mA)4-1/2 digits programmableDCV( 0-5V, 1-5V ,0-10V, 20mV, 100mV)Engineer unitFrequency(1Hz ~ 5KHz)66 Engineering unitsResistance(0-175 W, 0-400 W)Parameter ProtectAccuracy:Password entry(6 Digits)+/-0.15% of SpanLogging Rate:Response Time:1 Seconds ~ 1800 Seconds Per Pen50 msRecording Capability:Alarm Types:120 Hours(16 Points, 1 Data/Second)High & Low alarm, Incr. & Decr. alarm18936 Years(1 Point, 1 Data/Hour)Output:PC software:4-20 mA *4 points Maximum, Load:800WCompatible with Windows 2000/XP/VistaRelay, 3A/250V * 12 points MaximumDisplay24VDC, 65 mA *4 points MaximumTrend, Digital, Circular, Alarm, BargraphDigit Input:Totalizer2 Points MaximumConvert functionStorage Memory:Can be save as excel files128 MB(on board)Enclosure:Recycling Mode:NEMA 3 / IP 54Newest Data over-writes to oldest dataWeight:Recording Data Shift:2.6 Kg maximumUSB memory(2GB) / SD Card(2GB)Dimensions:Display update Rate:144 mm (W) * 144 mm (H) * 219 mm (D)1 SecondAmbient Temperature:Keyboard:-10 to +60 oC6 Keys (Page,Left,Right,Up,Down,Enter) Ambient Humidity:for programming and display control10% to 85%RH (at 5 to 40 oC )Parameter Storage:Power Supply:Operation Parameters are stored by 85-260VAC, 50/60HzEEPROM for more then 10 yearsVibration Test: 10~60Hz ,10m/S2 for 3 hours Power Consumption: <=20 W Communication: RS232 / RS485 (MODBUS Protocol) ผู้ดูแลระบบ 05/02/2018
10
ADP9000L : Smart Differential Pressure Transmitter
ADP9000L Series
ADP9000L series is a digital differential pressure transmitter designed for industrial level measurement applications. The ADP9000L can be configured to provide intergrated solutions for a broad range of pressure and flow measurement applications.
FEATURES
● Updating time of output current in 200 ms ● Improved performance, increased accuracy and greater stability ● Two years stability of 0.15% ● 0.075% accuracy ● Parameter setting by keypad directly ● 4-20 mA output plus direct digital HART communication ● Automatic zero calibration by push-button ● Explosion proof and weather proof housing
SPECIFICATION
Process Fluid:Display:Liquid, Gas of Vapor5 Digits programmable & 0-100% BargraphApplication:Display Unit:Liquid Level, Differential Pressure,Standard 22 different engineering unitGauge Pressure, Absolute Pressure5 Digits programmable for special unitMeasuring Range:Keyboard:0 - 6.2 Kpa ~ 0 - 37 Kpa ( Minimum )3 internal keys for programming0 - 4.0 Mpa ~ 0 - 25.0 Mpa ( Maximum )and output settingTurndown Ratio:Current Output:100 : 14 - 20 mA 2 wires with Hart SignalAccuracy:Load+/- 0.075% of spanRohm=(Vdc-9)*50 Stability:Power Supply:+/-0.15% of URL for 2 years9 - 36 VDCWorking Temperature:Digital Communication:-40 to +250 oCHart Protocol (Compatible)Max. Pressure:Damping:40 Mpa (Dependent on flange rating)0 - 32 secondsMaterial:Response Time:Flange/Adapter200 mSCarbon Steel / Stainless Steel 304 /Turn on Time:Stainless Steel 316 2 Seconds with minimum dampingDiaphragmZero Calibration:Stainless Steel 316L / Hastelloy B /Automatic calibration by push-buttonHastelloy C / Monel / TantalumCable Entry:Bolts & Nuts1/2" NPT( Female ) / M20 Conduit ThreadsCarbon Steel / Stainless Steel 316Temperature Effect:Name / Tag Plate+/-0.18% of span per 20 oCStainless Steel 304 / Stainless Steel 316EMI/RFI Effect:Converter HousingFollow SAMA PMC 33.1 from 20 to 1000Low copper cast aluminum alloy withMHz and for field strengths up to 30 V/mpolyurethane, light blue paintProcess connection:Fill FluidHigh Pressure SideSilicone / High Temperature Silicone1-1/2", 2", 3", 4" FlangesFluorine Oil / Vegetable OilANSI / DIN / JIS / Tri-ClampProtection Class:Extended DiaphragmIP67 ( Standard )2", 4", 6" lengthIntrinsically Safe EEx ia IIC T5 ( Standard )Low Pressure SideExplosion proof Ex D IIB T51/4 - 18 NPT , 1/2 - 14 NPT Ambient Temperature: -25 to +85 oC Dimensions: 102 mm (W) * 188 mm (H) * 189 mm (D) Weight: 8 - 15 Kg ผู้ดูแลระบบ 05/02/2018
ADP9000L Series
ADP9000L series is a digital differential pressure transmitter designed for industrial level measurement applications. The ADP9000L can be configured to provide intergrated solutions for a broad range of pressure and flow measurement applications.
FEATURES
● Updating time of output current in 200 ms ● Improved performance, increased accuracy and greater stability ● Two years stability of 0.15% ● 0.075% accuracy ● Parameter setting by keypad directly ● 4-20 mA output plus direct digital HART communication ● Automatic zero calibration by push-button ● Explosion proof and weather proof housing
SPECIFICATION
Process Fluid:Display:Liquid, Gas of Vapor5 Digits programmable & 0-100% BargraphApplication:Display Unit:Liquid Level, Differential Pressure,Standard 22 different engineering unitGauge Pressure, Absolute Pressure5 Digits programmable for special unitMeasuring Range:Keyboard:0 - 6.2 Kpa ~ 0 - 37 Kpa ( Minimum )3 internal keys for programming0 - 4.0 Mpa ~ 0 - 25.0 Mpa ( Maximum )and output settingTurndown Ratio:Current Output:100 : 14 - 20 mA 2 wires with Hart SignalAccuracy:Load+/- 0.075% of spanRohm=(Vdc-9)*50 Stability:Power Supply:+/-0.15% of URL for 2 years9 - 36 VDCWorking Temperature:Digital Communication:-40 to +250 oCHart Protocol (Compatible)Max. Pressure:Damping:40 Mpa (Dependent on flange rating)0 - 32 secondsMaterial:Response Time:Flange/Adapter200 mSCarbon Steel / Stainless Steel 304 /Turn on Time:Stainless Steel 316 2 Seconds with minimum dampingDiaphragmZero Calibration:Stainless Steel 316L / Hastelloy B /Automatic calibration by push-buttonHastelloy C / Monel / TantalumCable Entry:Bolts & Nuts1/2" NPT( Female ) / M20 Conduit ThreadsCarbon Steel / Stainless Steel 316Temperature Effect:Name / Tag Plate+/-0.18% of span per 20 oCStainless Steel 304 / Stainless Steel 316EMI/RFI Effect:Converter HousingFollow SAMA PMC 33.1 from 20 to 1000Low copper cast aluminum alloy withMHz and for field strengths up to 30 V/mpolyurethane, light blue paintProcess connection:Fill FluidHigh Pressure SideSilicone / High Temperature Silicone1-1/2", 2", 3", 4" FlangesFluorine Oil / Vegetable OilANSI / DIN / JIS / Tri-ClampProtection Class:Extended DiaphragmIP67 ( Standard )2", 4", 6" lengthIntrinsically Safe EEx ia IIC T5 ( Standard )Low Pressure SideExplosion proof Ex D IIB T51/4 - 18 NPT , 1/2 - 14 NPT Ambient Temperature: -25 to +85 oC Dimensions: 102 mm (W) * 188 mm (H) * 189 mm (D) Weight: 8 - 15 Kg ผู้ดูแลระบบ 05/02/2018
9
AUF600 : Ultrasonic Flowmeter
AUF600 Series
AUF600 series is a portable transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive liquid measurement of clean homgeneous fluids. Based on microprocessor and programmable flow measurement techniques the process flow can be accurately measured without interrupting the flow and with low installation costs.
FEATURES
● 4 line LCD display flowrate, totalizer & signal condition ● The flowmeter is designed in high accuracy +/-1.0% ● Small sized (200 * 92 * 32mm) and light-weight (538 g) ● Wide range, Velocities( 0.01 ~ +/- 32 m/s) ● Ni-MH Battery lasts for over 10 hours continuous operation ● Transducers suitable for pipe sizes from 15 to 6000 mm ● Built-in magnet in transducers, no need for steady tool on pipe ● Data logger which records flowrate, date, total flow,signal condition... etc ● Response time less than 1 second
SPECIFICATION
Measuring Principle:Keypad:Transit time difference18 Key with tactile actionPipe Size:Response Time:SS Type : 15 mm ~ 100 mm (1/2" ~ 4")Less than 1 secondMS Type : 50 mm ~ 700 mm (2" ~ 28")Flow Velocity:M Type : 50 mm ~ 700 mm (2" ~ 28")0.01 ~ +/- 32 m/sL Type : 300 mm ~ 6000 mm (12" ~ 240")Resolution:Pipe Material:0.0001 m/sCast Iron, Stainless Steel, Ductile IronAmbient Temperature:Copper, PVC, Aluminum, Asbestos-20 ~ +50 oCFiberglass... etcAmbient Humidity:Liner Material:90% RH or LessTar Epoxy, Rubber, Mortar, Polypropylene,Built-in Battery:Polystyrol, Polystyrene, Polyester, Ebonite,Ni-MH BatteryPolyethylene, Teflon... etcOperation Time:Display:> 10 Hours4 Line LCD with illuminationCharger:Flowrate90 ~ 260Vac 50/60 Hz, 8-12 Hr charging5 digit with decimal pointData Storage:TotalizerOperation parameters and totalizer8 digit, Forward, Reverse & Net valuesfigures are stored by EEPROM for moreEngineer Unitthan 10 yearsM3, Liter, US Gallon, Imperial Gallon,Data Logger:Million Gallon, Cubic Feet, US Barrels,Limitless overwriting in 64 columnsImperial Barrels, Oil Barrel(Flowrate, totalizer, time, date included) Time UnitAlarm:Second, Minute, Hour, DayHigh/Low with buzzerOtherPower Consumption:Velocity, Date, Time, Signal conditionLess than 2WAccuracy:Dimensions:+/- 1% ~ +/- 2% of reading (0.5 ~ 30 m/s)200 * 92 * 32 mm+/- 0.5% of reading (Online calibration)Weight:Repeatability:0.54 Kg+/-0.2% of readingProtection Class: Converter IP65 Sensor IP68 (Submersible) ผู้ดูแลระบบ 05/02/2018
AUF600 Series
AUF600 series is a portable transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive liquid measurement of clean homgeneous fluids. Based on microprocessor and programmable flow measurement techniques the process flow can be accurately measured without interrupting the flow and with low installation costs.
FEATURES
● 4 line LCD display flowrate, totalizer & signal condition ● The flowmeter is designed in high accuracy +/-1.0% ● Small sized (200 * 92 * 32mm) and light-weight (538 g) ● Wide range, Velocities( 0.01 ~ +/- 32 m/s) ● Ni-MH Battery lasts for over 10 hours continuous operation ● Transducers suitable for pipe sizes from 15 to 6000 mm ● Built-in magnet in transducers, no need for steady tool on pipe ● Data logger which records flowrate, date, total flow,signal condition... etc ● Response time less than 1 second
SPECIFICATION
Measuring Principle:Keypad:Transit time difference18 Key with tactile actionPipe Size:Response Time:SS Type : 15 mm ~ 100 mm (1/2" ~ 4")Less than 1 secondMS Type : 50 mm ~ 700 mm (2" ~ 28")Flow Velocity:M Type : 50 mm ~ 700 mm (2" ~ 28")0.01 ~ +/- 32 m/sL Type : 300 mm ~ 6000 mm (12" ~ 240")Resolution:Pipe Material:0.0001 m/sCast Iron, Stainless Steel, Ductile IronAmbient Temperature:Copper, PVC, Aluminum, Asbestos-20 ~ +50 oCFiberglass... etcAmbient Humidity:Liner Material:90% RH or LessTar Epoxy, Rubber, Mortar, Polypropylene,Built-in Battery:Polystyrol, Polystyrene, Polyester, Ebonite,Ni-MH BatteryPolyethylene, Teflon... etcOperation Time:Display:> 10 Hours4 Line LCD with illuminationCharger:Flowrate90 ~ 260Vac 50/60 Hz, 8-12 Hr charging5 digit with decimal pointData Storage:TotalizerOperation parameters and totalizer8 digit, Forward, Reverse & Net valuesfigures are stored by EEPROM for moreEngineer Unitthan 10 yearsM3, Liter, US Gallon, Imperial Gallon,Data Logger:Million Gallon, Cubic Feet, US Barrels,Limitless overwriting in 64 columnsImperial Barrels, Oil Barrel(Flowrate, totalizer, time, date included) Time UnitAlarm:Second, Minute, Hour, DayHigh/Low with buzzerOtherPower Consumption:Velocity, Date, Time, Signal conditionLess than 2WAccuracy:Dimensions:+/- 1% ~ +/- 2% of reading (0.5 ~ 30 m/s)200 * 92 * 32 mm+/- 0.5% of reading (Online calibration)Weight:Repeatability:0.54 Kg+/-0.2% of readingProtection Class: Converter IP65 Sensor IP68 (Submersible) ผู้ดูแลระบบ 05/02/2018
8
AUF750 : Ultrasonic Flowmeter
AUF750 Series
AUF750 series is a fixed mounted, transit-time ultrasonic Flowmeter. It features clamp-on style transducers for non-invasive measurement of clean homogeneous liquid processes. This user friendly microprocessor based, field programmable flowmeter ensures that the flow of existing processes can be performed without interrupting the flow and has very low installation costs.
FEATURES
• 4 line LCD display with flowrate, totalizer & signal condition • Stores up 64 Day/Month/Year Totalizer daily value • Batch control function • Wide range velocities of 0.01 ~ +/- 32 m/s • Transducers for pipe size from 15 to 6000 mm • High accuracy of +/-0.5% of reading • Built-in magnet in transducers, no need for steady tool on metal pipe • Data logger function, include date, totalizer, signal condition... etc • Response time less than 1 second
SPECIFICATION
Measuring Principle:Keypad:Transit time difference16 Key with tactile actionPipe Size:Response Time:S Type : 15 mm ~ 100 mm (1/2" ~ 4")Less than 1 secondM Type : 50 mm ~ 1000 mm (2" ~ 40")Flow Velocity:L Type : 300 mm ~ 6000 mm (12" ~ 240")0.01 ~ +/- 32 m/sHS Type : 15 mm ~ 100 mm (1/2" ~ 4¡¡À) Resolution:HM Type: 50 mm ~ 1000 mm (2" ~ 40¡¡À)0.0001 m/sPipe Material:Ambient Temperature:Cast Iron, Stainless Steel, Ductile Iron-20 ~ +50 oCCopper, PVC, Aluminum, Fiberglass... etc.Mounting:Liner Material:Wall mountingTar Epoxy, Rubber, Mortar, Polypropylene,Max. Cable Length:Polystyrol, Polyethylene, Teflon¡ etc300 MDisplay:Power Consumption:4 Line LCD with illuminationLess than 2WFlowratePower Supply:5 digit with decimal point90 ~ 260Vac 50/60 Hz or 8-36VdcTotalizerData Storage:8 digit, Forward, Reverse & Net values.Operation parameters and totalizer Engineer Unitfigures are stored by EEPROM for moreM3, Liter, US Gallon, Imperial Gallon,than 10 yearsMillion Gallon, Cubic Feet, US Barrels,Output:Imperial Barrels, Oil Barrel4-20 mA or 0-20 mATime UnitPulse Output:Second, Minute, Hour, Day1- 9999 HzOtherData Logger:Velocity, Date, Time, Signal condition.Limitless overwriting in 64 columnsAccuracy:(Flowrate, totalizer, time, date included)+/- 1% ~ +/- 2% of reading (0.5 ~ 30 m/s)Alarm:+/- 0.5% of reading (Online calibration)High/Low with buzzerRepeatability:Communication:+/-0.2% of readingRS-232Temperature Input:Dimensions:4-20 mA * 2 points for BTU calculation235 * 205 * 95 mmFunctionWeight: T, Measurements for Thermal Energy1.5 KgProtection Class:ConverterIP65SensorIP68 (Submersible) ผู้ดูแลระบบ 05/02/2018
AUF750 Series
AUF750 series is a fixed mounted, transit-time ultrasonic Flowmeter. It features clamp-on style transducers for non-invasive measurement of clean homogeneous liquid processes. This user friendly microprocessor based, field programmable flowmeter ensures that the flow of existing processes can be performed without interrupting the flow and has very low installation costs.
FEATURES
• 4 line LCD display with flowrate, totalizer & signal condition • Stores up 64 Day/Month/Year Totalizer daily value • Batch control function • Wide range velocities of 0.01 ~ +/- 32 m/s • Transducers for pipe size from 15 to 6000 mm • High accuracy of +/-0.5% of reading • Built-in magnet in transducers, no need for steady tool on metal pipe • Data logger function, include date, totalizer, signal condition... etc • Response time less than 1 second
SPECIFICATION
Measuring Principle:Keypad:Transit time difference16 Key with tactile actionPipe Size:Response Time:S Type : 15 mm ~ 100 mm (1/2" ~ 4")Less than 1 secondM Type : 50 mm ~ 1000 mm (2" ~ 40")Flow Velocity:L Type : 300 mm ~ 6000 mm (12" ~ 240")0.01 ~ +/- 32 m/sHS Type : 15 mm ~ 100 mm (1/2" ~ 4¡¡À) Resolution:HM Type: 50 mm ~ 1000 mm (2" ~ 40¡¡À)0.0001 m/sPipe Material:Ambient Temperature:Cast Iron, Stainless Steel, Ductile Iron-20 ~ +50 oCCopper, PVC, Aluminum, Fiberglass... etc.Mounting:Liner Material:Wall mountingTar Epoxy, Rubber, Mortar, Polypropylene,Max. Cable Length:Polystyrol, Polyethylene, Teflon¡ etc300 MDisplay:Power Consumption:4 Line LCD with illuminationLess than 2WFlowratePower Supply:5 digit with decimal point90 ~ 260Vac 50/60 Hz or 8-36VdcTotalizerData Storage:8 digit, Forward, Reverse & Net values.Operation parameters and totalizer Engineer Unitfigures are stored by EEPROM for moreM3, Liter, US Gallon, Imperial Gallon,than 10 yearsMillion Gallon, Cubic Feet, US Barrels,Output:Imperial Barrels, Oil Barrel4-20 mA or 0-20 mATime UnitPulse Output:Second, Minute, Hour, Day1- 9999 HzOtherData Logger:Velocity, Date, Time, Signal condition.Limitless overwriting in 64 columnsAccuracy:(Flowrate, totalizer, time, date included)+/- 1% ~ +/- 2% of reading (0.5 ~ 30 m/s)Alarm:+/- 0.5% of reading (Online calibration)High/Low with buzzerRepeatability:Communication:+/-0.2% of readingRS-232Temperature Input:Dimensions:4-20 mA * 2 points for BTU calculation235 * 205 * 95 mmFunctionWeight: T, Measurements for Thermal Energy1.5 KgProtection Class:ConverterIP65SensorIP68 (Submersible) ผู้ดูแลระบบ 05/02/2018
7
ADP9000 : Smart Differential Pressure Transmitter
ADP9000 SeriesADP9000 series is a digital differential pressure transmitter designed for industrial pressure measurement applications.The ADP9000 can be configured to provide integrated solutions for a broad range of pressure and flow measurement applications.
FEATURES• Updating time of output current in 200 ms• Improved performance, increased accuracy and greater stability• Two years stability of 0.2%• 0.075% accuracy• Parameter setting by keypad directly• 4-20 mA output plus direct digital HART communication• Automatic zero calibration by press-button• Explosion proof and weather proof housing
SPECIFICATION
Process Fluid:Display:Liquid, Gas of Vapor5 Digits programmable & 0-100% BargraphApplication:Display Unit:Liquid Level, Differential Pressure,Standard 22 different engineering unitGauge Pressure, Absolute Pressure5 Digits programmable for special unitMeasuring Range:Keyboard:0 - 6.2 Kpa ~ 0 - 37 Kpa ( Minimum )3 internal keys for programming0 - 4.0 Mpa ~ 0 - 25.0 Mpa ( Maximum )and output settingTurndown Ratio:Current Output:100:01:004 - 20 mA 2 wires with Hart SignalAccuracy:Load+/- 0.075% of spanRohm=(Vdc-9)*50 Stability:Power Supply:+/-0.15% of URL for 2 years9 - 36 VDCWorking Temperature:Digital Communication:-40 to +250 oCHart Protocol (Compatible)Max. Pressure:Damping:40 Mpa (Dependent on flange rating)0 - 32 secondsMaterial:Response Time:Flange/Adapter200 mSCarbon Steel / Stainless Steel 304 /Turn on Time:Stainless Steel 316 2 Seconds with minimum dampingDiaphragmZero Calibration:Stainless Steel 316L / Hastelloy B /Automatic calibration by push-buttonHastelloy C / Monel / TantalumCable Entry:Bolts & Nuts1/2" NPT( Female ) / M20 Conduit ThreadsCarbon Steel / Stainless Steel 316Temperature Effect:Name / Tag Plate+/-0.18% of span per 20 oCStainless Steel 304 / Stainless Steel 316EMI/RFI Effect:Converter HousingFollow SAMA PMC 33.1 from 20 to 1000Low copper cast aluminum alloy withMHz and for field strengths up to 30 V/mpolyurethane, light blue paintProcess connection:Fill FluidHigh Pressure SideSilicone / High Temperature Silicone1-1/2", 2", 3", 4" FlangesFluorine Oil / Vegetable OilANSI / DIN / JIS / Tri-ClampProtection Class:Extended DiaphragmIP67 ( Standard )2", 4", 6" lengthIntrinsically Safe EEx ia IIC T5 ( Standard )Low Pressure SideExplosion proof Ex D IIB T51/4 - 18 NPT , 1/2 - 14 NPTAmbient Temperature:-25 to +85 oCDimensions:102 mm (W) * 188 mm (H) * 189 mm (D)Weight:8 - 15 Kg ผู้ดูแลระบบ 05/02/2018
ADP9000 SeriesADP9000 series is a digital differential pressure transmitter designed for industrial pressure measurement applications.The ADP9000 can be configured to provide integrated solutions for a broad range of pressure and flow measurement applications.
FEATURES• Updating time of output current in 200 ms• Improved performance, increased accuracy and greater stability• Two years stability of 0.2%• 0.075% accuracy• Parameter setting by keypad directly• 4-20 mA output plus direct digital HART communication• Automatic zero calibration by press-button• Explosion proof and weather proof housing
SPECIFICATION
Process Fluid:Display:Liquid, Gas of Vapor5 Digits programmable & 0-100% BargraphApplication:Display Unit:Liquid Level, Differential Pressure,Standard 22 different engineering unitGauge Pressure, Absolute Pressure5 Digits programmable for special unitMeasuring Range:Keyboard:0 - 6.2 Kpa ~ 0 - 37 Kpa ( Minimum )3 internal keys for programming0 - 4.0 Mpa ~ 0 - 25.0 Mpa ( Maximum )and output settingTurndown Ratio:Current Output:100:01:004 - 20 mA 2 wires with Hart SignalAccuracy:Load+/- 0.075% of spanRohm=(Vdc-9)*50 Stability:Power Supply:+/-0.15% of URL for 2 years9 - 36 VDCWorking Temperature:Digital Communication:-40 to +250 oCHart Protocol (Compatible)Max. Pressure:Damping:40 Mpa (Dependent on flange rating)0 - 32 secondsMaterial:Response Time:Flange/Adapter200 mSCarbon Steel / Stainless Steel 304 /Turn on Time:Stainless Steel 316 2 Seconds with minimum dampingDiaphragmZero Calibration:Stainless Steel 316L / Hastelloy B /Automatic calibration by push-buttonHastelloy C / Monel / TantalumCable Entry:Bolts & Nuts1/2" NPT( Female ) / M20 Conduit ThreadsCarbon Steel / Stainless Steel 316Temperature Effect:Name / Tag Plate+/-0.18% of span per 20 oCStainless Steel 304 / Stainless Steel 316EMI/RFI Effect:Converter HousingFollow SAMA PMC 33.1 from 20 to 1000Low copper cast aluminum alloy withMHz and for field strengths up to 30 V/mpolyurethane, light blue paintProcess connection:Fill FluidHigh Pressure SideSilicone / High Temperature Silicone1-1/2", 2", 3", 4" FlangesFluorine Oil / Vegetable OilANSI / DIN / JIS / Tri-ClampProtection Class:Extended DiaphragmIP67 ( Standard )2", 4", 6" lengthIntrinsically Safe EEx ia IIC T5 ( Standard )Low Pressure SideExplosion proof Ex D IIB T51/4 - 18 NPT , 1/2 - 14 NPTAmbient Temperature:-25 to +85 oCDimensions:102 mm (W) * 188 mm (H) * 189 mm (D)Weight:8 - 15 Kg ผู้ดูแลระบบ 05/02/2018
6
AMF601 : Electromagnetic Flowmeter
AMF601 Series
AMF601 Series is a sanitary type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 25mm to 100 mm. The AMF601 is widely used for drink water, milk, food & beverage juice and many other industrial fluid.AMF601 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES• Light and compact version• Flow Velocity range: 0-12 m/s, precise in low flow applications • IDF Tri-Clamp or Union screw Connection• Excellent for high pressure application• Protection class: IP68 available; sensor submersible• PTFE Liner is suitable for vacuum tube• High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)• With Forward / Reverse flowrate measurement function
SPECIFICATION
Size:Cable Entry:25, 32, 40, 50, 65, 80, 100 mmStandard :PG11 Option:1/2"NPTF1", 1-1/4", 1-1/2", 2", 2-1/2", 3" , 4"Ambient Temperature:Measuring Range:-25 to +60 oCVelocity 0-0.25 m/s min.Process Connection: 0-12 m/s max.IDF Tri-ClampMaterial:Union ScrewTube & ConnectionGrounding Resistance:Stainless Steel 304 or 316Must be less than 10 ΩCoil HousingAccuracy:Stainless Steel 304 (Standard)+/-0.5% reading (Velocity >=0.5m/s)Stainless Steel 316 (Option)+/-0.2% readingLiner(Suitable for AMC3100 converter only)PTFE+/-0.0025 m/s (Velocity < 0.5 m/s)ElectrodeTemperature:Stainless Steel 316L-40 to +150 oCHastelloy BMax. Pressure:Hastelloy C10 Kg/cm2 (Standard)Titanium40 Kg/cm2 (Option)TantalumExplosion Proof:Tungsten CarbideExd(ib)ibqIIBT5 Platinum(with AMC3100/AMC4000 only)Protection Class:Junction box IP67, Body IP68IP68 (Submersible)Conductivity:More than 5 uS/cm ผู้ดูแลระบบ 05/02/2018
AMF601 Series
AMF601 Series is a sanitary type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 25mm to 100 mm. The AMF601 is widely used for drink water, milk, food & beverage juice and many other industrial fluid.AMF601 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES• Light and compact version• Flow Velocity range: 0-12 m/s, precise in low flow applications • IDF Tri-Clamp or Union screw Connection• Excellent for high pressure application• Protection class: IP68 available; sensor submersible• PTFE Liner is suitable for vacuum tube• High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)• With Forward / Reverse flowrate measurement function
SPECIFICATION
Size:Cable Entry:25, 32, 40, 50, 65, 80, 100 mmStandard :PG11 Option:1/2"NPTF1", 1-1/4", 1-1/2", 2", 2-1/2", 3" , 4"Ambient Temperature:Measuring Range:-25 to +60 oCVelocity 0-0.25 m/s min.Process Connection: 0-12 m/s max.IDF Tri-ClampMaterial:Union ScrewTube & ConnectionGrounding Resistance:Stainless Steel 304 or 316Must be less than 10 ΩCoil HousingAccuracy:Stainless Steel 304 (Standard)+/-0.5% reading (Velocity >=0.5m/s)Stainless Steel 316 (Option)+/-0.2% readingLiner(Suitable for AMC3100 converter only)PTFE+/-0.0025 m/s (Velocity < 0.5 m/s)ElectrodeTemperature:Stainless Steel 316L-40 to +150 oCHastelloy BMax. Pressure:Hastelloy C10 Kg/cm2 (Standard)Titanium40 Kg/cm2 (Option)TantalumExplosion Proof:Tungsten CarbideExd(ib)ibqIIBT5 Platinum(with AMC3100/AMC4000 only)Protection Class:Junction box IP67, Body IP68IP68 (Submersible)Conductivity:More than 5 uS/cm ผู้ดูแลระบบ 05/02/2018
5
AMF500 : Electromagnetic Flowmeter
AMF500 SeriesAMF500 Series is a wafer type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 25 to 200 mm.AMF500 is widely used for tap-water, waste water, food & beverage, pulp & paper and many other industrial fluid.AMF500 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES• Light and compact version• Flow Velocity range: 0-12 m/s, precise in low flow applications• It comes any flanges such as ANSI, DIN, JIS... etc• Excellent for high pressure application• Protection class: IP68 available; sensor submersible• FEP Liner is suitable for vacuum tube• High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)• With Forward / Reverse flowrate measurement function
SPECIFICATIONSize:Cable Entry:25, 32, 40, 50, 65, 80, 100, 125, 150, 200 mmStandard :PG11 Option:1/2"NPTFMeasuring Range:Ambient Temperature:Velocity 0-0.25 m/s min.-25 to +60 oC 0-12 m/s max.Process Connection:Material:WaferMeasuring TubeFlange type:Stainless Steel 304JIS 10K / JIS 20K / JIS 40KCoil HousingANSI 150# / ANSI 300# / ANSI 600#Carbon Steel (Standard)DIN PN 10 / PN 16 / PN25 / PN 40Stainless Steel 304 (Option)Grounding Resistance:Stainless Steel 316 (Option)Must be less than 10 ΩLiner:Accuracy:FEP+/-0.5% read-out values (Velocity >=0.5 m/s)Protection Class:+/-0.2% read-out valuesJunction box IP67, Body IP68(Suitable for AMC3100 converter only)IP 68 (Submersible)+/-0.0025 m/s (Velocity < 0.5 m/s)Conductivity:Temperature:More than 5 uS/cm-40 to +180 oCElectrode & Grounding:Max. Pressure:Stainless Steel 316L16 Kg/cm2 (Standard)Hastelloy B40 Kg/cm2 (Option)Hastelloy CExplosion Proof:TitaniumExd(ib)ibqIIBT5 Tantalum(with AMC3100/AMC4000 only)Tungsten CarbidePlatinum ผู้ดูแลระบบ 05/02/2018
AMF500 SeriesAMF500 Series is a wafer type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 25 to 200 mm.AMF500 is widely used for tap-water, waste water, food & beverage, pulp & paper and many other industrial fluid.AMF500 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES• Light and compact version• Flow Velocity range: 0-12 m/s, precise in low flow applications• It comes any flanges such as ANSI, DIN, JIS... etc• Excellent for high pressure application• Protection class: IP68 available; sensor submersible• FEP Liner is suitable for vacuum tube• High accuracy of +/-0.4% value of reading (or+/-0.2% value of reading)• With Forward / Reverse flowrate measurement function
SPECIFICATIONSize:Cable Entry:25, 32, 40, 50, 65, 80, 100, 125, 150, 200 mmStandard :PG11 Option:1/2"NPTFMeasuring Range:Ambient Temperature:Velocity 0-0.25 m/s min.-25 to +60 oC 0-12 m/s max.Process Connection:Material:WaferMeasuring TubeFlange type:Stainless Steel 304JIS 10K / JIS 20K / JIS 40KCoil HousingANSI 150# / ANSI 300# / ANSI 600#Carbon Steel (Standard)DIN PN 10 / PN 16 / PN25 / PN 40Stainless Steel 304 (Option)Grounding Resistance:Stainless Steel 316 (Option)Must be less than 10 ΩLiner:Accuracy:FEP+/-0.5% read-out values (Velocity >=0.5 m/s)Protection Class:+/-0.2% read-out valuesJunction box IP67, Body IP68(Suitable for AMC3100 converter only)IP 68 (Submersible)+/-0.0025 m/s (Velocity < 0.5 m/s)Conductivity:Temperature:More than 5 uS/cm-40 to +180 oCElectrode & Grounding:Max. Pressure:Stainless Steel 316L16 Kg/cm2 (Standard)Hastelloy B40 Kg/cm2 (Option)Hastelloy CExplosion Proof:TitaniumExd(ib)ibqIIBT5 Tantalum(with AMC3100/AMC4000 only)Tungsten CarbidePlatinum ผู้ดูแลระบบ 05/02/2018
4
AVF7000 : Vortex Flowmeter
AVF7000 SeriesAVF7000 is a Vortex Flowmeter based on Von Karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe.
The AVF7000 is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either flange or wafer connection. Standard configurationhas local indication for flowrate and total flow as well as 4-20mA with HART signal and pulse output functions. The microprocessor design can filter out erroneous signals as well as interfence caused by pipe vibration.
FEATURES• Simplified setup and self-diagnostic functions• Auto. Temperature & Pressure compensation • 4-20mA with HART signal and pulse outputs, user selectable• A very wide selection of sizes• Wide temperature range up to 420 oC• Non-volatile memory for setup and calibration
SPECIFICATION
Size:Local Display:15,20,25,32,40,50,65,80,100,125,1502 lines LCD200,250,300,350,400,450,500mm6 digit flowrateMeasuring Range:8 digit TotalizerSteam - 1.6 to 540,000 Kg/HrCurrent Output:Gas - 3 to 46,000 M3/Hr4-20 mA (2 wire) with HART signalLiquid - 0.3 to 4950 M3/HrLoadMaterial:Max. 1000 ΩStainless Steel 301 / 304 / 316Pulse Output:Accuracy Liquid:Scale Pulse +/-0.7% value of readingLoadGas & Steam1000 Ω - 5000 Ω+/-1.0% value of readingCommunication:Unit:HART(Compatible) or RS485 (MODBUS Protocol)Nm3/h, Nm3/m, Nm3/s, m3/d, m3/h, m3/mData Storage:m3/s, l/h, l/m, l/s, t/d, t/h, t/m, kg/d, kg/hOperation parameter and totalizerkg/m, kg/s, g/h, g/m, g/sfigures are stored by EEPROM for moreRepeatability:than 10 years+/-0.2% value of readingHousing Material:Process Connection:Aluminum AlloyFlange / WaferCable Entry:Flange typeStandard :M20 Option:1/2"NPTFJIS 10K / JIS 20K / JIS 40KPower supply:ANSI 150# / ANSI 300# / ANSI 600#12-32 VDCDIN PN 10 / PN 16 / PN25 / PN 40Ni-MH Battery (3 years working Hours)Wafer typeKeyPad:DN40~DN250 without Temp. / Pressure Sensor3 internal keys for programmingTemperature:and display control-40 ~ +280 oC (Standard)Option:-40 ~ +420 oC (Optional)Pressure SensorAmbient Temperature:Pressure compensation-20 ~ +60 oCSignal outputPressure:0-30 mV DC (20 uA Power supply)78 Kg/cm2 (Max.)Temperature SensorProtection Class:Temperature compensationIP 65Signal OutputExplosion Proof, Exd IIC T6PT1000 (2 wires)Intrinsically Safe, Eex ia IIC T4 ผู้ดูแลระบบ 05/02/2018
AVF7000 SeriesAVF7000 is a Vortex Flowmeter based on Von Karman theory of vortices generated by a bluff body in the pipe. The number of vortices are linearly proportional to the volumetric flow in the pipe.
The AVF7000 is versatile flowmeter widely used for Gases, Steam & Liquid applications. There are no moving parts and comes with either flange or wafer connection. Standard configurationhas local indication for flowrate and total flow as well as 4-20mA with HART signal and pulse output functions. The microprocessor design can filter out erroneous signals as well as interfence caused by pipe vibration.
FEATURES• Simplified setup and self-diagnostic functions• Auto. Temperature & Pressure compensation • 4-20mA with HART signal and pulse outputs, user selectable• A very wide selection of sizes• Wide temperature range up to 420 oC• Non-volatile memory for setup and calibration
SPECIFICATION
Size:Local Display:15,20,25,32,40,50,65,80,100,125,1502 lines LCD200,250,300,350,400,450,500mm6 digit flowrateMeasuring Range:8 digit TotalizerSteam - 1.6 to 540,000 Kg/HrCurrent Output:Gas - 3 to 46,000 M3/Hr4-20 mA (2 wire) with HART signalLiquid - 0.3 to 4950 M3/HrLoadMaterial:Max. 1000 ΩStainless Steel 301 / 304 / 316Pulse Output:Accuracy Liquid:Scale Pulse +/-0.7% value of readingLoadGas & Steam1000 Ω - 5000 Ω+/-1.0% value of readingCommunication:Unit:HART(Compatible) or RS485 (MODBUS Protocol)Nm3/h, Nm3/m, Nm3/s, m3/d, m3/h, m3/mData Storage:m3/s, l/h, l/m, l/s, t/d, t/h, t/m, kg/d, kg/hOperation parameter and totalizerkg/m, kg/s, g/h, g/m, g/sfigures are stored by EEPROM for moreRepeatability:than 10 years+/-0.2% value of readingHousing Material:Process Connection:Aluminum AlloyFlange / WaferCable Entry:Flange typeStandard :M20 Option:1/2"NPTFJIS 10K / JIS 20K / JIS 40KPower supply:ANSI 150# / ANSI 300# / ANSI 600#12-32 VDCDIN PN 10 / PN 16 / PN25 / PN 40Ni-MH Battery (3 years working Hours)Wafer typeKeyPad:DN40~DN250 without Temp. / Pressure Sensor3 internal keys for programmingTemperature:and display control-40 ~ +280 oC (Standard)Option:-40 ~ +420 oC (Optional)Pressure SensorAmbient Temperature:Pressure compensation-20 ~ +60 oCSignal outputPressure:0-30 mV DC (20 uA Power supply)78 Kg/cm2 (Max.)Temperature SensorProtection Class:Temperature compensationIP 65Signal OutputExplosion Proof, Exd IIC T6PT1000 (2 wires)Intrinsically Safe, Eex ia IIC T4 ผู้ดูแลระบบ 05/02/2018
3
AMF900 : Electromagnetic Flowmeter
AMF900 Series
AMF900 Series is a flange type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 6 to 2000mm. AMF900 is widely used for tap-water, waste water, food & beverage pulp &paper and many other industrial fluid. AMF900 Serieselectromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES
• Various liner and electrode satisfy most industrial applications• Flow Velocity range: 0-12 m/s, precise in low flow applications • It comes any flanges such as, ANSI, DIN, JIS... etc• Excellent for high pressure application• Protection class: IP68 available; sensor submersible• FEP Liner is suitable for vacuum tube• High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading)• With Forward/Reverse flowrate measurement function
SPECIFICATIONSize:Electrode & Grounding:6,10,15,20, 25,32,40,50,65,80,100,125Stainless Steel 316L150,200,250,300,350,400,450,500,600Hastelloy B700,800,900,1000,1200,1400,1600Hastelloy C1800,2000 mmTitaniumMeasuring Range:TantalumVelocity 0 - 0.25 m/s min.Platinum 0 - 12 m/s max.Tungsten CarbideMaterial:Cable Entry:Measuring TubeStandard :PG11 Option:1/2"NPTFStainless Steel 304Ambient Temperature:Flange-25 to +60 oCCarbon Steel (Standard)Process Connection:Stainless Steel 304 (Option)Flange Stainless Steel 316, 316L (Option)Flange Type:Coil HousingJIS 10K / JIS 20K / JIS 40KCarbon Steel (Standard)ANSI 150# / ANSI 300# / ANSI 600#Stainless Steel 304 (Option)DIN PN 10 / PN 16 / PN25 / PN 40Stainless Steel 316,316L (Option)Grounding Resistance:Liner:Must be less than 10 Polyurethane (25-600 mm)Accuracy:Neoprene (50-2000 mm)+/-0.4% read-out values (Velocity >=0.5 m/s)FEP (6-300 mm)+/-0.0025 m/s (Velocity < 0.5 m/s)PTFE (25-800 mm)+/-0.2% read-out valuesPFA (6-300 mm)(Suitable for AMC3100 converter only)Protection Class:Temperature:Junction box IP67, Body IP68-10 ~ +60oC (Polyurethane, PU)IP 68 (Submersible)-20 ~ +70oC (Neoprene)Conductivity:-40 ~ +180oC (FEP)More than 5 uS/cm-40 ~ +180oC (PTFE/PFA)Explosion Proof:Max. Pressure:Exd(ib)ibqIIBT5 (with AMC3100/AMC4000 only)350 Kg/cm2 ผู้ดูแลระบบ 30/01/2018
AMF900 Series
AMF900 Series is a flange type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 6 to 2000mm. AMF900 is widely used for tap-water, waste water, food & beverage pulp &paper and many other industrial fluid. AMF900 Serieselectromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
FEATURES
• Various liner and electrode satisfy most industrial applications• Flow Velocity range: 0-12 m/s, precise in low flow applications • It comes any flanges such as, ANSI, DIN, JIS... etc• Excellent for high pressure application• Protection class: IP68 available; sensor submersible• FEP Liner is suitable for vacuum tube• High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading)• With Forward/Reverse flowrate measurement function
SPECIFICATIONSize:Electrode & Grounding:6,10,15,20, 25,32,40,50,65,80,100,125Stainless Steel 316L150,200,250,300,350,400,450,500,600Hastelloy B700,800,900,1000,1200,1400,1600Hastelloy C1800,2000 mmTitaniumMeasuring Range:TantalumVelocity 0 - 0.25 m/s min.Platinum 0 - 12 m/s max.Tungsten CarbideMaterial:Cable Entry:Measuring TubeStandard :PG11 Option:1/2"NPTFStainless Steel 304Ambient Temperature:Flange-25 to +60 oCCarbon Steel (Standard)Process Connection:Stainless Steel 304 (Option)Flange Stainless Steel 316, 316L (Option)Flange Type:Coil HousingJIS 10K / JIS 20K / JIS 40KCarbon Steel (Standard)ANSI 150# / ANSI 300# / ANSI 600#Stainless Steel 304 (Option)DIN PN 10 / PN 16 / PN25 / PN 40Stainless Steel 316,316L (Option)Grounding Resistance:Liner:Must be less than 10 Polyurethane (25-600 mm)Accuracy:Neoprene (50-2000 mm)+/-0.4% read-out values (Velocity >=0.5 m/s)FEP (6-300 mm)+/-0.0025 m/s (Velocity < 0.5 m/s)PTFE (25-800 mm)+/-0.2% read-out valuesPFA (6-300 mm)(Suitable for AMC3100 converter only)Protection Class:Temperature:Junction box IP67, Body IP68-10 ~ +60oC (Polyurethane, PU)IP 68 (Submersible)-20 ~ +70oC (Neoprene)Conductivity:-40 ~ +180oC (FEP)More than 5 uS/cm-40 ~ +180oC (PTFE/PFA)Explosion Proof:Max. Pressure:Exd(ib)ibqIIBT5 (with AMC3100/AMC4000 only)350 Kg/cm2 ผู้ดูแลระบบ 30/01/2018
2
APT8000 : Smart Pressure Transmitter
APT8000 Series
APT8000 series is a digital pressure transmitter designed for industrial pressure measurement applications. The APT8000 offer configurations for gauge pressure, absolute pressure and vacuum including integrated solutions for industrial applications.
FEATURES
• Updating time of output current in 90 ms• Improved performance, increased accuracy and greater stability• Two years stability of 0.15%• 0.075% accuracy• Parameter setting by keypad directly• 4-20 mA output plus direct digital HART communication• Automatic zero calibration by press-button• Explosion proof and weather proof housing
SPECIFICATION
Process Fluid:Display:Liquid, Gas or Vapor5 Digits programmable & 0-100% BargraphApplication:Display Unit:Absolute Pressure, Gauge Pressure,Standard 22 different engineering unitVacuum5 Digits programmable for special unitMeasuring Range:Keyboard:0 - 10 Kpa ~ 0 - 30 Kpa ( Minimum )3 internal keys for Programming0 - 32 Mpa ~ 0 - 70 Mpa ( Maximum )and output settingTurndown Ratio:Current Output:100 : 14 - 20 mA 2 wires with Hart SignalAccuracy:Load+/- 0.075% of spanRohm=(Vdc-9)*50 Stability:Power Supply:+/-0.15% of URL for 2 years9 ~ 36 VDCWorking Temperature:Digital Communication:-25 to +95 oCHart Protocol (Compatible)Max. Pressure:Damping:70 Mpa0 - 32 secondsMaterial:Response Time:Connection90 mSSUS 304 / SUS 316 Mounting:DiaphragmDirect installation or bracket on 2" PipeSUS 316L / TantalumHumidity Limit:Housing0 to 100% Relative HumidityLow copper cast aluminum alloy withTurn on Time:polyurethane, light blue paint2 Seconds with minimum dampingName / Tag PlateZero Calibration:Stainless Steel 304 / Stainless Steel 316Automatic zero calibration by push-buttonCable Entry:Ambient Temperature:M20 Conduit Threads / 1/2" NPT( Female )-25 to +85 oCProcess Connection:Dimensions: 1/2" NPT, 1/2" BSP 102 mm ( W ) * 160 mm ( H ) * 130 mm ( D )Temperature Effect:Weight:+/-0.18% of span per 20 oC1.3 KgOver Pressure Limit:Protection Class:120% of Full ScaleIP67 ( Standard )Vibration Effect:Intrinsically Safe EEx ia IIC T5 (Standard)+/-0.05% of URL per g to 200 Hz in anyExplosion proof Ex D IIB T5axis EMI/RFI Effect: Follow SAMA PMC 33.1 from 20 to 1000 MHz and for field strengths up to 30 V/m ผู้ดูแลระบบ 30/01/2018
APT8000 Series
APT8000 series is a digital pressure transmitter designed for industrial pressure measurement applications. The APT8000 offer configurations for gauge pressure, absolute pressure and vacuum including integrated solutions for industrial applications.
FEATURES
• Updating time of output current in 90 ms• Improved performance, increased accuracy and greater stability• Two years stability of 0.15%• 0.075% accuracy• Parameter setting by keypad directly• 4-20 mA output plus direct digital HART communication• Automatic zero calibration by press-button• Explosion proof and weather proof housing
SPECIFICATION
Process Fluid:Display:Liquid, Gas or Vapor5 Digits programmable & 0-100% BargraphApplication:Display Unit:Absolute Pressure, Gauge Pressure,Standard 22 different engineering unitVacuum5 Digits programmable for special unitMeasuring Range:Keyboard:0 - 10 Kpa ~ 0 - 30 Kpa ( Minimum )3 internal keys for Programming0 - 32 Mpa ~ 0 - 70 Mpa ( Maximum )and output settingTurndown Ratio:Current Output:100 : 14 - 20 mA 2 wires with Hart SignalAccuracy:Load+/- 0.075% of spanRohm=(Vdc-9)*50 Stability:Power Supply:+/-0.15% of URL for 2 years9 ~ 36 VDCWorking Temperature:Digital Communication:-25 to +95 oCHart Protocol (Compatible)Max. Pressure:Damping:70 Mpa0 - 32 secondsMaterial:Response Time:Connection90 mSSUS 304 / SUS 316 Mounting:DiaphragmDirect installation or bracket on 2" PipeSUS 316L / TantalumHumidity Limit:Housing0 to 100% Relative HumidityLow copper cast aluminum alloy withTurn on Time:polyurethane, light blue paint2 Seconds with minimum dampingName / Tag PlateZero Calibration:Stainless Steel 304 / Stainless Steel 316Automatic zero calibration by push-buttonCable Entry:Ambient Temperature:M20 Conduit Threads / 1/2" NPT( Female )-25 to +85 oCProcess Connection:Dimensions: 1/2" NPT, 1/2" BSP 102 mm ( W ) * 160 mm ( H ) * 130 mm ( D )Temperature Effect:Weight:+/-0.18% of span per 20 oC1.3 KgOver Pressure Limit:Protection Class:120% of Full ScaleIP67 ( Standard )Vibration Effect:Intrinsically Safe EEx ia IIC T5 (Standard)+/-0.05% of URL per g to 200 Hz in anyExplosion proof Ex D IIB T5axis EMI/RFI Effect: Follow SAMA PMC 33.1 from 20 to 1000 MHz and for field strengths up to 30 V/m ผู้ดูแลระบบ 30/01/2018
1
ARC800 : Paperless Recorder
ARC800 Series
ARC800 Series Paperless Recorder features the most advanced technology. It can be applied across a broad scope of industrial applications. ARC800 is the product which with multi-channels, complete functions, easy operation, high accuracy,low power but high performance. And the series overcome the old-fashioned paperless recorder, which has less channels, multiple installation and space-consuming problem.
FEATURES
• DIN Size (96mm*96mm), 320*240 Pixels, TFT truecolor (LCD) • 4MB memory installed inside, applied to long terms data record• Common input signal: mA, Include VDC, T/C, RTD, Hz etc.• High Accuracy +/-0.15% of Reading• 2 relay outputs, 1 analog output (4-20mA),1 (24VDC) power supply output• 4 channels Max.input• 24VDC Aux. Power supply available for 2 wires system• Display / Record Single-point, Multi-point, Trend, Totalizer, Bargraph• The recorded data could be stored in USB memory & SD memory card and transferred to computer for soft analysis
SPECIFICATION
Number of Inputs:Display:1- 4 Channels3.5" color-screen LCDInput:Trend & BargraphT/C (K, S, B, E, J, N, T, R,N, etc.)Vertical / HorizontalRTD, CU50, CU53, BA1, BA2DigitalDCA (4-20 mA, 0-10 mA, 0-20 mA)4-1/2 digits programmableDCV ( 0-5V, 1-5V , 20mV, 100mV)Engineer UnitFrequency (1Hz ~ 5KHz)66 different engineering unitsResistance (0-400 )Parameter ProtectionAccuracy:Password entry (6 Digits)+/-0.15% of SpanLogging Rate:Response Time:1 Second ~ 1800 Seconds Per Data50 msRecording Capability:Alarm Types:72 Hours (4 Points, 1 Data/Second)High & Low alarm, Incr. & Decr. alarm118 Years (1 Point, 1 Data/Hour)Output:PC Software:4-20 mA, Load 750 *1 pointWindows 2000/XP/Vista/Win7Relay, 3A/250V * 2 pointsDisplay24VDC, 60 mA *1 pointTrend, Digital, Circular, Alarm, BargraphDigit Input:Totalizer2 Points MaximumConvert FunctionStorage Memory:Saved as excel files4 MB (on board)Protection Class:Recycling Mode:NEMA 3 / IP 54Newest Data overwrites to oldest dataWeight:Recording Data Shift:0.5 Kg MaximumUSB memory (8GB) / SD Card (4GB)Dimensions:Display Update Rate:96mm (W) * 96 mm (H) *110 mm (D)1 SecondAmbient Temperature:Keyboard:-10 ~ +60 oC6 Keys (Page, Left, Right, Up, Down, Enter) Ambient Humidity:for programming and display control10% ~ 85%RH (5 ~ 40oC )Parameter Storage:Power Supply:Operation parameters are stored by 85-260VAC, 50/60HzEEPROM for more than 10 years24VDC Vibration Test: 10~60Hz ,10m/S2 for 3 hours Power Consumption: <=10 W Communication: RS232 / RS485 (MODBUS Protocal) ผู้ดูแลระบบ 30/01/2018
ARC800 Series
ARC800 Series Paperless Recorder features the most advanced technology. It can be applied across a broad scope of industrial applications. ARC800 is the product which with multi-channels, complete functions, easy operation, high accuracy,low power but high performance. And the series overcome the old-fashioned paperless recorder, which has less channels, multiple installation and space-consuming problem.
FEATURES
• DIN Size (96mm*96mm), 320*240 Pixels, TFT truecolor (LCD) • 4MB memory installed inside, applied to long terms data record• Common input signal: mA, Include VDC, T/C, RTD, Hz etc.• High Accuracy +/-0.15% of Reading• 2 relay outputs, 1 analog output (4-20mA),1 (24VDC) power supply output• 4 channels Max.input• 24VDC Aux. Power supply available for 2 wires system• Display / Record Single-point, Multi-point, Trend, Totalizer, Bargraph• The recorded data could be stored in USB memory & SD memory card and transferred to computer for soft analysis
SPECIFICATION
Number of Inputs:Display:1- 4 Channels3.5" color-screen LCDInput:Trend & BargraphT/C (K, S, B, E, J, N, T, R,N, etc.)Vertical / HorizontalRTD, CU50, CU53, BA1, BA2DigitalDCA (4-20 mA, 0-10 mA, 0-20 mA)4-1/2 digits programmableDCV ( 0-5V, 1-5V , 20mV, 100mV)Engineer UnitFrequency (1Hz ~ 5KHz)66 different engineering unitsResistance (0-400 )Parameter ProtectionAccuracy:Password entry (6 Digits)+/-0.15% of SpanLogging Rate:Response Time:1 Second ~ 1800 Seconds Per Data50 msRecording Capability:Alarm Types:72 Hours (4 Points, 1 Data/Second)High & Low alarm, Incr. & Decr. alarm118 Years (1 Point, 1 Data/Hour)Output:PC Software:4-20 mA, Load 750 *1 pointWindows 2000/XP/Vista/Win7Relay, 3A/250V * 2 pointsDisplay24VDC, 60 mA *1 pointTrend, Digital, Circular, Alarm, BargraphDigit Input:Totalizer2 Points MaximumConvert FunctionStorage Memory:Saved as excel files4 MB (on board)Protection Class:Recycling Mode:NEMA 3 / IP 54Newest Data overwrites to oldest dataWeight:Recording Data Shift:0.5 Kg MaximumUSB memory (8GB) / SD Card (4GB)Dimensions:Display Update Rate:96mm (W) * 96 mm (H) *110 mm (D)1 SecondAmbient Temperature:Keyboard:-10 ~ +60 oC6 Keys (Page, Left, Right, Up, Down, Enter) Ambient Humidity:for programming and display control10% ~ 85%RH (5 ~ 40oC )Parameter Storage:Power Supply:Operation parameters are stored by 85-260VAC, 50/60HzEEPROM for more than 10 years24VDC Vibration Test: 10~60Hz ,10m/S2 for 3 hours Power Consumption: <=10 W Communication: RS232 / RS485 (MODBUS Protocal) ผู้ดูแลระบบ 30/01/2018
1 / 1